IMPLANT-ASSOCIATED PATHOLOGY: AN ALGORITHM FOR IDENTIFYING PARTICLES IN HISTOPATHOLOGIC SYNOVIALIS/SLIM DIAGNOSTICS

封面


如何引用文章

全文:

详细

In histopathologic SLIM diagnostic (synovial-like interface membrane, SLIM) apart from diagnosing periprosthetic infection particle identification has an important role to play. The differences in particle pathogenesis and variability of materials in endoprosthetics explain the particle heterogeneity that hampers the diagnostic identification of particles. For this reason, a histopathological particle algorithm has been developed. With minimal methodical complexity this histopathological particle algorithm offers a guide to prosthesis material-particle identification. Light microscopic-morphological as well as enzyme-histochemical characteristics and polarization-optical proporties have set and particles are defined by size (microparticles, macroparticles and supra- macroparticles) and definitely characterized in accordance with a dichotomous principle. Based on these criteria, identification and validation of the particles was carried out in 120 joint endoprosthesis pathological cases. A histopathological particle score (HPS) is proposed that summarizes the most important information for the orthopedist, material scientist and histopathologist concerning particle identification in the SLIM.

作者简介

V. Krenn

Center for Histology, Cytology and Molecular Diagnostics

编辑信件的主要联系方式.
Email: krenn@patho-trier.de
俄罗斯联邦

P. Thomas

Hospital and Outpatients’ Clinic for Dermatology and Allergology, Ludwig Maximilian University

Email: noemail@neicon.ru
俄罗斯联邦

M. Thomsen

DRK Hospital, Orthopedics and Trauma Surgery

Email: noemail@neicon.ru
俄罗斯联邦

S. Usbeck

CeramTec GmbH

Email: noemail@neicon.ru
俄罗斯联邦

L. Scheuber

CeramTec GmbH

Email: noemail@neicon.ru
俄罗斯联邦

F. Boettner

Hospital for Special Surgery/HSS

Email: noemail@neicon.ru
俄罗斯联邦

W. Rüther

University Medical Center Hamburg Eppendorf

Email: noemail@neicon.ru
俄罗斯联邦

F. Hopf

Center for Histology, Cytology and Molecular Diagnostics

Email: noemail@neicon.ru
俄罗斯联邦

S. Müller

Center for Histology, Cytology and Molecular Diagnostics

Email: noemail@neicon.ru
俄罗斯联邦

M. Krukemeyer

Paracelsus-Kliniken Deutschland Gmbh

Email: noemail@neicon.ru
俄罗斯联邦

T. Gehrke

HELIOS ENDO-Klinik

Email: noemail@neicon.ru
俄罗斯联邦

D. Kendoff

HELIOS ENDO-Klinik

Email: noemail@neicon.ru
俄罗斯联邦

A. Tiemann

SRH Zentralklinikum Suhl, Klinik für Orthopädie und Unfallchirurgie

Email: noemail@neicon.ru
俄罗斯联邦

M. Huber

Institute of Pathology and Bacteriology, Otto Wagner Hospital

Email: noemail@neicon.ru
俄罗斯联邦

参考

  1. Algami A.D., Huk O.L., Pelmus M. Metallosis-induced iliopsoas bursal cyst causing venous obstruction and lower-limb swelling after metal-on-metal THA. Orthopedics. 2012;35(12):1066-1069.
  2. Asencio G., Essig J., Nourissat Ch., Caremeau C. Abnormal local tissue reaction after total hip arthroplasty with a modular Co-Cr femoral piece. SOFCOT, Abstract 269 , 2011.
  3. Bader R., Bergschmidt P., Fritsche A., Ansorge S., Thomas P., Mittelmeier W. Alternative Werkstoffe und Lösungen in der Knieendoprothetik für Patienten mit Metallallergie [Alternative materials and solutions in total knee arthroplasty for patients with metal allergy]. Orthopäde. 2008;37(2):136-142.
  4. Bader R., Mittelmeier W., Steinhauser E. Versagensanalyse von Knieendoprothesen: Grundlagen und methodische Ansätze zur Schadensanalyse [Failure analysis of total knee replacement. Basics and methodological aspects of the damage analysis]. Orthopäde. 2006;35(9): 896-903.
  5. Bergschmidt P., Bader R., Mittelmeier W. Metal hypersensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component - A case report. Knee. 2012;19:144-147.
  6. Bergschmidt P., Bader R., Kluess D., Zietz C., Mittelmeier W. the all-ceramic knee endoprosthesis - the gap between expectation and experience with ceramic implants. Semin Arthro. 2012;23(4):262-267.
  7. Bertz S., Kriegsmann J., Eckardt A., Delank K., Drees P., Hansen T., Otto M. Correlation of quantitative histopathological morphology and quantitative radiological analysis during aseptic loosening of hip endoprotheses. J. Appl. Biomat. Biomech. 2006;4(3):153-164.
  8. Bos I. Gewebereaktionen um gelockerte Hüftgelenksendoprothesen. Eine histologische Studie an Sekundärkapseln und Interfacemembranen [Tissue reactions around loosend hip joint endoprostheses. A histological study of secondary capsules and interface membranes]. Orthopäde. 2001;30(11):881-889.
  9. Bos I., Berner J., Diebold J., Löhrs U. Histologische und morphometrische Untersuchungen an Femora mit stabilen Hüftgelenksendoprothesen. Z. Orthop. 1995;133:460-466.
  10. Bosch U., Zeichen J., Skutek M., Haeder L., van Griensven. Arthrofibrosis is the result of a T cell mediated immune response. Knee Surg. Sports Traumatol. Arthrosc. 2011;9(5):282-289.
  11. Campbell P., Ma S., Yeom B., McKellop H., Schmalzried T.P., Amstutz H.C. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. J. Biomed. Mater. Res. 1995;29(1):127-131.
  12. Campbell P., Shimmin A., Walter L., Solomon M. metal sensitivity as a cause of groin pain in metal-on metal hip resurfacing. J. Arthroplasty. 2008;23(7):1080-1085.
  13. Cooper H.J., Della Valle C.J., Berger R.A., Tetreault M., Paprosky W.G., Sporer S.M., Jacobs J.J. corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J. Bone Joint Surg. Am. 2012;94:1655-1661.
  14. Cooper H.J., Della Valle C.J., Jacobs J.J. biologic implications of taper corrosion in total hip arthroplasty. Semin Arthro. 2012;23(4):273-278.
  15. Fuerst M., Zustin J., Rüther W: Kristallarthropathien [Crystal arthropathies]. Der Pathologe. 2011;32(3):193-199.
  16. Gallo J., Kolár M., Novotný R., Riháková P., Tichá V. Pathogenesis of Prosthesis-Related Infection. Biomed. Papers. 2003;147(1):27 - 35.
  17. Gao X., He R.X., Yan S.G., Wu L.D. dermatitis associated with chromium following total knee arthroplasty. J. Arthroplasty. 2011;26(4):665.e13-e16.
  18. Gill I.P.S., Webb J., Sloan K., Beaver R.J. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J. Bone Joint Surg. Br. 2012;94:895-900.
  19. Haddad F.S., Thakrar R.R., Hart A.J., Skinner J.A., Nargol A.V.F., Nolan J.F., Gill H.S., Murray D.W., Blom A.W., Case C.P. Metal-on-metal bearings. The Evidence so far. J. Bone Joint Surg. Br. 2011;93:572-579.
  20. Hansen T., Otto M., Buchhorn G.H., Scharnweber D., Gaumann A., Delank K.S., Eckardt A., Willert H.G., Kriegsmann J., Kirkpatrick C.J. New aspects in the histological examination of polyethylene wear particles in failed total joint replacements. Acta Histochem. 2002;104: 263-269.
  21. Harvie P., Giele H., Fang C., Ansorge O., Ostlere S., Gibbons M., Whitwell D. The treatment of femoral neuropathy due to pseudotumour caused by metal-on-metal resurfacing arthroplasty. Hip Int. 2008;18:313-320.
  22. Hirakawa K., Bauer T.W., Stulberg B.N., Wilde A.H. Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty. J. Biomed. Mater. Res. 1996;31(2): 257-263.
  23. Huber M., Reinisch G., Trettenhahn G., Zweymüller K., Lintner F. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomaterialia. 2009;5:172-180.
  24. Jacobs J.J., Gilbert J.L., Urban R.M. Corrosion of metal orthopaedic implants. J. Bone Joint Surg. Am. 1998;80:268-282.
  25. Jameson S., Ramisetty N., Langton D., Webb J., Logishetty R., Nargol A. ALVAL: Diagnosis, incidence and treatment in contemporary metal-on-metal bearings. Abstract F11, EFORT 2008.
  26. Kemp M.A., Mitra A., Mendes da Costa, Spencer R.F. Bearing exchange in the management of pseudotumors. Ann. R. Coll. Surg. Engl. 2013;95:266-270.
  27. Kosukegawa I., Nagoya S., Kaya M., Sasaki K., Sasaki M., Yamashita T. Revision total hip arthroplasty due to pain from hypersensitivity to cobalt-chromium in total hip arthroplasty. J. Arthroplasty. 2011;26(6):978.e1-e3.
  28. Krenn V., Thomas P., Thomsen M., Kretzer J.P. et al. Histopathological particle algorithm: Particle identification in the synovia and the SLIM. Z. Rheumatol. 2014; 73(7):639-649.
  29. Krenn V., Poremba C., Schneider J., Kendoff D. et al. Histopathological differential diagnostics in context of joint implant allergic reactions. Orthopade. 2013;42(8):614-621.
  30. Krenn V., Kretzer J.P., Thomas P., Thomsen M. et al. Update on endoprosthesis pathology: Particle algorithm for particle identification in the SLIM, Seminars in Arthroplasty. 2013; 24(4):265-275.
  31. Kretzer J.P., Zietz C., Schröder C., Reinders J., Middelborg L., Paulus A., Sonntag R., Bader R., Utzschneider S. Grundlagen zur tribologischen Analyse von Endoprothesen [Principles of tribological analysis of endoprostheses]. Orthopäde. 2012; 41(10):844-852.
  32. Kubo T., Sawada K., Hirakawa K., Shimizu C., Takamatsu T., Hirasawa Y. Histiocyte reaction in rabbit femurs to UHMWPE, metal, and ceramic particles in different sizes. J. Biomed. Mater. Res. 1999;45(4):363-369.
  33. Laffer R., Ruef C. Diagnose und Therapie von Gelenkprotheseninfektionen. Z. Rheumatol. 2006;65:12-17.
  34. Langton D.J., Sidaginamale R., Lord J.K., Nargol A.V., Joyce T.J. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint. Res. 2012;1:56-63.
  35. Lintner F., Böhm G., Huber M., Zweymüller K. Histologisch-immunhistologische, morphometrische und bakteriologische Untersuchungen des Gelenkkapselgewebes nach Reoperation totaler Hüftendoprothesen unter Verwendung der Metall/ Metallpaarung. Osteol. 2013;12: 233-246.
  36. Mahendra G., Pandit H., Kliskey K., Murray D., Gill H.S., Athanasou N. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop. 2009;80(6):653-659.
  37. Mao X., Tay G.H., Godbolt D.B., Crawford R.W. Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty. J. Arthroplasty. 2012;27(3) :493.e13-e17.
  38. Marculescu C.E., Berbari E.F., Cockerill F.R. 3rd, Osmon D.R. Fungi, mycobacteria, zoonotic and other organisms in prosthetic joint infection. Clin. Orthop. 2006;451:64-72.
  39. Maurer-Ertl W., Friesenbichler J., Liegl-Atzwanger B., Kuerzl G., Windhager R., Leithner A. noninflammatory pseudotumor simulating venous thrombosis after metal-on-metal hip resufacing. Orthopedics. 2011;34(10):678.
  40. Meyer H., Mueller T., Goldau G., Chamaon K., Ruetschi M., Lohmann C.H. Corrosion at the cone/ taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin. Orthop. 2012;470(11):3101-3108.
  41. Morawietz L., Classen R.A., Schröder J.H., Dynybil C., Perka C. et al. Proposal for a histopathological consensus classification of the periprosthetic interface membrane. J. Clin. Pathol. 2006;59:591-597.
  42. Mortier J., Engelhardt M. Foreign body reaction in carbon fiber prosthesis implantation in the knee joint-case report and review of the literature. Z. Orthop. 2000;138(5):390-394.
  43. Otto M., Kriegsmann J., Gehrke T., Bertz S. Abriebpartikel: Schlüssel der aseptischen Prothesenlockerung? [Wear particles: key to aseptic prosthetic loosening?] Pathologe. 2006;27(6):447-460.
  44. Post D.Z., Orozco F.R., Ong A.C. metal sensitivity after TKA presenting with systemic dermatitis and hair loss. Orthopedics. 2013;36(4):e525-e528.
  45. Rajpura A., Porter M.L., Gambhir A.K., Freemont A.J., Board T.N. Clinical experience of revision of metal on metal hip arthroplasty for aseptic lymphocyte dominated vasculitis associated lesions (ALVAL).Hip Int. 2010;21(1):43-51.
  46. Scully W.F., Teeny S.M. pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics. 2013;36(5):e666-e670.
  47. Shahrdar C., Campbell P., Mirra J., Dorr L.D. Painful metal-on-metal total hip arthroplasty. J. Arthroplasty. 2006;21(2):289-293.
  48. Siemon B., Schubert T., Grifka J., Borisch N. Ungewöhnliche Komplikation der Silikonsynovialitis am rheumatischen Handgelenk [Unusual complication of silicon synovitis in the rheumatoid wrist]. Z. Rheumatol. 2004;63(3):230-234.
  49. Thakur R.R., Ast M.P., McGraw M., Bostrom M.P., Rodriguez J.A., Parks M.L. Severe persistant synovitis after cobalt-chromium total knee arthroplasty requiring revision. Orthopedics. 2013; 36(4):e520-e524.
  50. Thomas P., Braathen L.R., Dörig M., Auböck J., Nestle F., Werfel T., Willert H.G. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and periimplant T-lymphocytic inflammation. Allergy. 2009;64(8):1157-1165.
  51. Thomas P., Schuh A., Ring J., Thomsen M. Orthopädischchirurgische Implantate und Allergien [Orthopedic surgical implants and allergies: Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery)]. Hautarzt. 2008;59:220-229.
  52. Thomas P., Thomas M., Summer B., Dietrich K., Zauzig M., Steinhauser E., Krenn V., Arnholdt H., Flaig M.J. Impaired wound-healing, local eczema, and chronic inflammation following titanium osteosynthesis in a nickel and cobalt-allergic patient: a case report and review of the literature. J. Bone Joint Surg. Am. 2011;93(11):e611-e615.
  53. Thomas P., von der Helm C., Schopf C., Thomsen M., Frommelt L., Schneider J., Flaig M., Krenn V., Mazoochian F., Summer B. Periimplant histology and cytokine pattern in metal-allergic knee arthroplasty patients with improvement after revision with hypoallergenic materials. Semin Arthro. 2012;23(4):268-272.
  54. Thomsen M., Kretzer J.P., Krenn V., Thomas P. Unterschiedliche Erscheinungsbilder bei Patienten mit Metall/Metall-Gleitpaarungs-Prothesen [Different symptoms in patients with prostheses with metal-metal bearings]. Orthopäde. 2013;42(8):637-642.
  55. Thomsen M., Rozak M., Thomas P. Pain in a chromium-allergic patient with knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA. Acta Orthop. 2011;82(3):386-388.
  56. Urban R.M., Jacobs J.J., Gilbert J.L., Galante J.O. Migration of corrosion products from modular hip prostheses. J. Bone Joint Surg. Am. 1994;76:1345-1359.
  57. Vundelinckx B.J., Luk A., Verhelst L.A., Schepper J.D.Taper corrosion in modular hip prostheses analysis of serum metal ions in 19 Patients. J. Arthroplasty. 2013;28(7):1218-1222.
  58. Watters T.S., Cardona D.M., Menon K.S., Vinson E.N., Bolognesi M.P., Dodd L.G. Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an underrecognized cause of prosthetic failure. Am. J. Clin. Pathol. 2010;134(6):886-893.
  59. Witzleb W.C., Hanisch U., Kolar N., Krummenauer F., Guenther K.P. Neo-capsule tissue reactions in metal-on-metal hip arthroplasty. Acta Orthop. 2007;78(2):211-220.
  60. Wolfarth D.L., Han D.W., Bushar G., Parks N.L. Separation and characterization of polyethylene wear debris from synovial fluid and tissue samples of revised knee replacements. J. Biomed. Mater. Res. 1997;34(1):57-61.