Several biomechanical parameters of standing and walking in 50 patients with osteoarthrosis after total knee arthroplasty were evaluated. The patients were randomly divided in two equal groups: in the first group the surgery was performed with computer navigation system and in the second - with traditional instruments. After TKA with computer navigation centers of common body pressure and legs pressure during standing phase improved significantly better than in traditional group. Walking parameters like step length, ground contact time and rhythm coefficient improved in both groups of patients but without significant difference. Thereby more precise orientation of implant that achieved during computer assisted TKA leads to better functional performance at 6 and 12 month after surgery.

About the authors

Y. A. Bezgodkov

ГБОУ ВПО «Санкт-Петербургская государственная педиатрическая медицинская академия» Минздравсоцразвития России

Author for correspondence.
Email: noemail@neicon.ru
Россия

N. N. Kornilov

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

A. I. Petukhov

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

T. A. Kulyaba

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

A. V. Selin

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

Y. I. Muranchic

ГУЗ «Рязанская областная клиническая больница»

Email: noemail@neicon.ru
Россия

I. I. Croitoru

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

V. L. Ignatenko

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

A. V. Saraev

ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России

Email: noemail@neicon.ru
Россия

References

  1. Безгодков, Ю.А. Оценка статики и походки у больных с патологией крупных суставов нижних конечностей / Ю.А. Безгодков // Материалы Х юбилейного Российского национального конгресса "Человек и его здоровье". - СПб., 2005. - С. 11.
  2. Мурылев, В.Ю. Оценка ближайших результатов тотального эндопротезирования коленного сустава с применением компьютерной навигации / В.Ю. Мурылев [и др.] // Вестник травматологии и ортопедии им. Н.Н. Приорова. - 2009. - № 1. - С. 29 - 33.
  3. Петухов, А.И. Анализ пространственного расположения компонентов эндопротеза коленного сустава и ранние функциональные результаты эндопротезирования с использованием компьютерной навигации / А.И. Петухов [и др.] // Вестник травматологии и ортопедии им. Н.Н. Приорова. - 2009. - № 3. - С. 51-55.
  4. Bertsch, C. Early clinical outcome after navigated total knee arthroplasty. Comparison with conventional implantation in TKA: a controlled and prospective analysis / C. Bertsch [et al.] // Orthopade. - 2007. -Bd. 36, Н. 8. - S. 739 - 745.
  5. Davies, A.P. Rating systems for total knee replacement / A.P. Davies // Knee. - 2002. - Bd. 9, N 4. - P. 261 - 266.
  6. Decking, R. On the outcome of computer-assisted total knee replacement / R. Decking [et al.] // Acta Chir. Orthop. Traumatol. Cech. - 2007. - Vol. 74, N 3. - P. 171 - 174.
  7. Fang, D.M. Coronal alignment in total knee arthroplasty: just how important is it / D.M. Fang, M.A. Ritter, K.E. Davis // J. Arthroplasty. - 2009. - Vol. 24, N 6. - P. 39 - 43.
  8. Haaker, R. Computer-assisted navigation increases precision of component placement in total knee arthroplasty / R. Haaker [et al.] // Clin. Orthop. - 2005. - N 433. - P. 152-159.
  9. Kamat, Y.D. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? / Y.D. Kamat [et al.] // Int. Orthop. - 2009. - Vol. 33, N 6. - P. 1567- 1570.
  10. Lutzner, J. Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study / J. Lutzner, K.P. Gunther, S. Kirschner // Knee Surg. Sports Traumatol. Arthrosc. - 2010. - Vol. 18, N 10. - P. 1339- 1344.
  11. Macule-Beneyto, F. Navigation in total knee arthroplasty. A multicenter study / F. Macule-Beneyto [et al.] // Int. Orthop. - 2006. - Vol. 30, N 6. - Р. 536 - 540.
  12. Maniar, R.N. Margin of error in alignment: a study undertaken when converting from conventional to computer-assisted total knee arthroplasty / R.N. Maniar [et al.] // J. Arthroplasty. - 2011. - Vol. 26, N 1. - P. 82 - 87.
  13. Peterlein, C.D. Clinical outcome and quality of life after computer-assisted total knee arthroplasty: results from a prospective, single-surgeon study and review of the literature / C.D. Peterlein [et al.] // Chir. Organi Mov. - 2009. - Vol. 93, N 3. - Р. 115-122.
  14. Picard, F. A quantitative method of effective soft tissue management for varus knees in total knee replacement surgery using navigational techniques / F. Picard [et al.] // Proc. Inst. Mech. Eng. - 2007. - Vol. 221, N 7. - P. 763 - 772.
  15. Siston, R.A. Surgical navigation for total knee arthroplasty: a perspective / R.A. Siston [et al.] // J. Biomech. - 2007. - Vol. 40, N 4. - P. 728 - 735.
  16. Spencer, J.M. Computer navigation versus conventional total knee replacement: no difference in functional results at two years / J.M. Spenser [et al.] // J. Bone Joint Surg. - 2007. - Vol. 89-B, N 4. - Р. 477 - 480.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c)



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies