Background. In recent decades, interest in proximal interphalangeal joint (PIPJ) arthroplasty has significantly increased around the world. At the same time, a growing number of operations entail an increase in the number of reinterventions.
The aim of the study — to determine the causes and evaluate the outcomes of revision interventions for proximal interphalangeal joint arthroplasty based on the data from a federal center for trauma and orthopedics.
Methods. We analyzed gender and age distribution of patients, the number of revisions, possible causes of implant failure, its localization and type, survival rate of the construct, surgical approaches. The study covers a 15-year period.
Results. Among 95 performed primary PIPJ arthroplasties, 15 (15.8%) cases of failure were observed in 14 patients. There was 1 periprosthetic fracture; 2 cases of implant fracture; instability of implant components — 12 cases associated with injury, increased physical activity and other causative factors. The maximum failure rate was detected in the II finger (31.6% of the number of initially implanted prostheses). After primary arthroplasty, instability was most often observed in hinged implants (SBI D.G.T. PIP joint implant and the RM Finger Mathys). The option for reintervention in 2 (16.7%) cases was PIPJ arthrodesis, in 11 (83.3%) — revision arthroplasty.
Conclusions. Despite the significant (15.8%) rate of adverse outcomes after proximal interphalangeal joint arthroplasty, most frequently caused by implant instability, the survival rate of the implants reaches up to 10 years in some cases and depends both on the type of prosthesis and the patient’s occupation. Overall, revision proximal interphalangeal joint arthroplasty allows for joint mobility preservation and statistically significantly reduces pain.
Full Text
INTRODUCTION
Injuries and diseases of the proximal interphalangeal joint (PIPJ), particularly osteoarthritis, affect approximately 15.5% of the population. Currently, PIPJ arthroplasty is becoming the preferred and most promising surgical option for restoring joint and overall hand function [1, 2, 3].
The concept of PIPJ arthroplasty first emerged in 1940 when M. Burman described the outcomes of Vitallium cup arthroplasty for the metacarpophalangeal and interphalangeal joints of the fingers [4]. Total PIPJ arthroplasty originated in the 1960s and was initially performed in patients with end-stage rheumatoid arthritis [5]. Early studies reported severe complications, including infection, periarticular fibrosis, and bone resorption. Over time, the indications for arthroplasty expanded to include severe post-traumatic damage, idiopathic osteoarthritis, and rarer systemic diseases such as juvenile idiopathic arthritis, gouty arthritis, and others [6, 7, 8, 9, 10].
Interest in this topic increased in the early 1970s, with the publication of studies focusing on the technological aspects, challenges, and initial outcomes of primary PIPJ arthroplasty. Since 2014, the number of annual publications on this subject has grown to 20-30 per year.
In recent decades, the global rise in primary PIPJ arthroplasty procedures has led to an increase in revision operations. Following implant removal, significant bone loss is often observed, which considerably limits the possibilities for re-operation. Revision arthroplasty demands a high level of surgical expertise and advanced implant systems.
The aim of this study was to determine the causes and evaluate the outcomes of revision interventions following proximal interphalangeal joint arthroplasty based on the data from a federal center for trauma and orthopedics.
METHODS
Study design: a retrospective continuous single-center study.
The study is based on the data from the medical information system regarding 95 PIPJ arthroplasty procedures performed at the Federal Center for Traumatology, Orthopedics, and Arthroplasty of the Ministry of Health of Russia (Cheboksary). The study covers a 15-year period (2009-2024).
We analyzed patient demographics (age and gender distribution), the number of revision operations, potential causes of implant failure, its localization and type, implant survival rate, and surgical approaches.
Revision PIPJ arthroplasty was defined as the replacement of at least one implant component (proximal or distal). Patients who underwent other interventions on the same joint after the primary arthroplasty were excluded.
Periprosthetic fractures, mechanical implant failure, and aseptic loosening were evaluated radiologically and, when necessary, using computed tomography.
A dorsal surgical approach was used along the previous operative scar, with proximal or distal extension if necessary. After implant removal, the final assessment of bone defects was performed. If cortical integrity was preserved, a larger prosthesis with cemented or cementless fixation was selected. In the early years of our experience, we did not prioritize intraoperative extensor mechanism reconstruction, relying instead on immobilization for 2-3 weeks postoperatively. However, with growing experience, we now consistently restore the extensor tendon, performing refixation of the central bundle to the base of the middle phalanx and, if necessary, reinforcing it by suturing the lateral bundles. Early rehabilitation is initiated in such cases. In cases of significant cortical bone defects following implant removal, PIPJ arthrodesis was performed.
PIPJ implant failure occurring within 2 years after primary arthroplasty was considered an early failure (Group I), and after 2 years – a late failure (Group II). Thus, all cases were divided into early and late failure groups.
For patients who underwent multiple revision operations, the total number of revisions was recorded. Implant survival rate was measured as the interval from primary to revision operation or, in cases of multiple revisions, from the previous to the current revision.
Follow-up evaluation of revision interventions included both objective (range of motion measured with a goniometer before and after surgery; X-ray examination) and subjective (pain severity according to the VAS criteria).
Statistical analysis
Statistical analysis was performed using Microsoft Excel 2007 and GraphPad software. Categorical data (gender, implant localization and type, causes of instability) were encoded as unordered categorical variables. Continuous variables were tested for normality using the Shapiro-Wilk test. Normally distributed variables were described using the mean value and standard deviation (SD), while non-normally distributed variables were expressed as the median and the lower and upper quartiles Me (Q1-Q3). In both cases, 95% confidence intervals (CI) were applied. Comparisons between groups were performed using the Mann-Whitney U test and Fisher’s exact test.
RESULTS
The gender composition of the sample included 44 (46.3%) men and 51 (53.7%) women. At the time of the primary operation, the mean age of the patients was 41.6 years (SD = 12.5; 37.4-42.6).
Among 95 performed primary PIPJ arthroplasties, 15 (15.8%) cases of adverse outcomes were identified in 14 patients (one woman underwent revision twice), including 6 (42.9%) men and 8 (57.1%) women, with an age range of 18-62 years and a mean age of 43.5 years (SD = 12.3; 41.2-54.8).
An assessment of the age composition of patients undergoing primary and revision PIPJ arthroplasty at the time of surgery revealed a significant predominance (60%) of patients aged 18 to 50 years (Figure 1).
Figure 1. Age distribution of patients at the time of surgery
Among 95 performed primary PIPJ arthroplasties, 15 (15.8%) cases of failure were observed in 14 patients. Among the causes of adverse outcomes, there was 1 (6.7%) periprosthetic fracture and 2 (13.3%) implant fractures. The most common reason for re-operation was component instability – 12 cases (80%), of which 3 were trauma-related, 4 were associated with high physical loads, and in 5 cases, the cause of implant failure remained undetermined. Thirteen (86.7%) operations were performed; two patients are awaiting planned hospital admission.
Among the identified cases of PIPJ prosthesis instability, 6 cases were classified as Group I (including one patient awaiting planned hospital admission), and 9 cases as Group II (including one patient also awaiting revision surgery).
PIPJ arthroplasties for the fingers from the II to the V were performed in the center. The highest number of operations was carried out on the III (42.1%) and the IV (35.8%) finger. However, the highest failure rate (PIPJ prosthesis instability) was observed in the II finger (6 out of 19 – 31.6% of the initially implanted prostheses) (Table 1).
Table 1. Failure rate of PIPJ prostheses
Parameter | Finger | |||||||
II | III | IV | V | |||||
Number of primary operations | Number of failures | Number of primary operations | Number of failures | Number of primary operations | Number of failures | Number of primary operations | Number of failures | |
Right hand, n | 12 | 5 | 29 | 3 | 16 | – | – | – |
Left hand, n | 7 | 1 | 11 | 3 | 18 | 3 | 2 | – |
Total | 19 | 6 | 40 | 6 | 34 | 3 | 2 | – |
Failure rate, % | 31.6 | 15.0 | 8.8 | – |
Instability was most frequently observed with hinged prostheses (SBI D.G.T. PIP joint implant and RM Finger Mathys).
The distribution of failed implants by type was as follows: SBI D.G.T. PIP joint implant (n = 11), RM Finger Mathys (n = 1), Moje ACAMO PIP (n = 1), and Swanson silicone implant (n = 2).
In two cases (16.7%), arthrodesis of the PIPJ was performed as a revision procedure, while in 11 cases (83.3%), revision arthroplasty was carried out. One patient underwent two revision arthroplasties: the first 3 years after the primary procedure and the second 7 years after the previous revision (Table 2).
Table 2. Causes of PIPJ prosthesis failures and outcomes of surgical treatment
Parameter | Implant fracture | Periprosthetic fracture | Cause | ||||||||||||
Trauma | High physical loads | Undetermined etiology | |||||||||||||
Number | 2 | 1 | 3 | 4 | 5 | ||||||||||
Removed implant | Mathys | Silicone | DGT SBI | DGT SBI | DGT SBI | DGT SBI | DGT SBI | DGT SBI | DGT SBI | DGT SBI | Moje | DGT SBI | DGT SBI | DGT SBI | Silicone |
Implanted prosthesis | Moje | Moje | – | DGT SBI | DGT SBI | Moje | DGT SBI | – | DGT SBI | DGT SBI | – | DGT SBI | Silicone | – | Silicone |
Treatment modality | RA | RA | AD | RA | RA | RA | RA | AD | RA | RA | – | RA | RA | – | RA |
Survival rate, years | 10 | 8 | 2 | 1 | 3 | 7 | <1 | 1 | 2 | 3 | 2 | 3 | 7 | 10 | 7 |
RA – revision arthroplasty; AD – arthrodesis.
Postoperatively, all patients reported reduced pain (p<0.05). The range of motion in each group either remained unchanged or decreased; however, achieving the maximum possible range of motion during follow-up was not feasible (Table 3).
Table 3. Evaluation of functional outcomes of revision PIPJ arthroplasty
Parameter | Group I (n = 5*) | р | Group II (n = 8*) | р | ||
Before operation | During follow-up | Before operation | During follow-up | |||
Pain severity according to the VAS scale, points | 6.4 (4.6-9.4) | 0.6 (0.3-1.7) | 0.0014** | 5.5 (3.7-7.3) | 0.5 (0.0-1.0)*** | 0.0002** |
Range of motion, deg. | 9.0 (0.8-19.2) | 11.0 (0.8-19.2) | 0.6811 | 8.8 (4.2-15.8) | 16.9 (7.0-23.0) | 0.0747 |
* – one patient in each group is awaiting planned hospital admission for revision operation; ** – statistically significant differences; *** – Me (Q1-Q3).
The mean survival rate of the removed implants during revision procedures was 4.5 years (SD = 3.3; 1.2-4.8), ranging from less than a year to 10 years.
DISCUSSION
The proximal interphalangeal joint plays a crucial role in full hand grip function, providing 85% of the flexion arc of the fingers, while the remaining 15% is provided by the distal interphalangeal joint [11, 12, 13]. The main advantage of arthroplasty is the preservation of motion despite the high rates of complications and revision operations [14, 15].
According to our study, the majority of patients were of working age with high physical activity levels, where both the aesthetic appearance of the hand and its optimal functionality were crucial, making joint mobility preservation particularly important.
It is worth noting that the variability in primary PIPJ arthroplasty outcomes depended on location. Our data indicate that PIPJ prosthesis failure is most frequently observed in the II finger. Literature suggests that the feasibility of PIPJ arthroplasty in the II finger remains controversial due to the significant lateral and axial rotational stresses during grip. Some authors report a fourfold increased risk of complications and advocate for arthrodesis as the method of choice for this joint pathology [16, 17]. However, T. Richards et al. dispute the preference for the PIPJ arthrodesis of the II finger as a default operation and support arthroplasty, particularly with silicone implants [18].
M.T. Milone et al. compared the II finger with three other fingers and concluded that the rate of deformities and complications associated with instability in case of the PIPJ arthroplasty of the III finger may be similar to that of the second one. E.R. Wagner et al. and M.T. Milone et al. suggest that the complication rate presents a relative contraindication for the PIPJ arthroplasty of both the II and the III finger [19, 20]. Our data show an increasing prevalence of the PIPJ prosthesis instability from the V to the II finger – 0.0%, 8.8%, 15.0%, and 31.6% for the V, IV, III, and II fingers, respectively.
Revision PIPJ arthroplasty presents a significant challenge. Minimal cortical bone remains after implant removal, and trabecular bone is largely absent in the medullary canals [21]. In our practice, we perform a dorsal surgical approach with subsequent refixation of the central bundle of the extensor tendon for both primary and revision procedures. However, literature actively discusses alternative approaches, such as palmar and lateral surgical approaches, along with their advantages and disadvantages [22, 23]. Selection of implant and surgical strategy remains a key issue in primary PIPJ arthroplasty [12, 24], as well as in case of revision interventions.
The aims of both primary and revision PIPJ arthroplasty include the reduction of pain, increased range of motion, restoration of the fingers’ biological axis, and improvement of hand function [25, 26, 27]. The present study demonstrated that revision arthroplasty statistically significantly reduces pain and pre-serves PIPJ mobility, confirming the findings of our previous study [28].
It should be noted that the change in the range of motion after revision surgery compared to preoperative levels is minimal, and arthrodesis remains the method of choice when bone integrity is compromised due to implant removal or periprosthetic fractures.
Several surgical methods exist for both arthrodesis and PIPJ fixation. Compression screw osteosynthesis has shown great results in terms of nonunion rates compared to Kirschner wire fixation. Over the past 10 years, there has been a growing number of publications on compres-sion techniques, suggesting a shift toward compression-based approaches. The limited data available on PIPJ arthrodesis lack clear indications for alternative techniques. Kirschner wire osteosynthesis remains relevant in cases of acute trauma with soft tissue defects or exten-sive bone loss following failed PIPJ arthroplasty [29, 30, 31, 32, 33]. Only large multicenter randomized controlled trials can determine the optimal PIPJ arthrodesis technique.
Study limitations
Limitations of this study are the small sample size and the insufficient amount of literature available for performing a meta-analysis of the issue.
CONCLUSIONS
The analysis of PIPJ arthroplasty outcomes in the federal center for trauma and orthopedics demonstrated the demand for this treatment, primarily among younger patients, likely due to their high functional requirements.
Despite the significant (15.8%) rate of adverse outcomes after primary operation, most frequently caused by implant instability, the survival rate of the implants reached up to 10 years in some cases and depended both on the type of prosthesis (hinged implants were more prone to instability) and the patient’s occupation (more than one-third of patients requiring revision intervention were engaged in heavy physical labor).
A notable trend was the increasing failure rate from the V to the II finger, reaching 31.6% for the latter, likely due to higher everyday functional loads. The primary surgical treatment for PIPJ prosthesis failure remains revision arthroplasty (83.3%), though arthrodesis is also justified in certain cases. Overall, re-operation for the failure of the proximal interphalangeal joint implant allows for joint mobility preservation and statistically significantly reduces pain.
The limited number of scientific papers on this issue highlights the need for further investigation through multicenter studies.
DISCLAIMERS
Author contribution
Fedotov P.V. — data acquisition, analysis and interpretation; drafting and editing the manuscript.
Kovalev D.V. — data acquisition, analysis and interpretation; drafting and editing the manuscript.
Nikolaev N.S. — study concept and design, editing the manuscript.
Mikhailov A.S. — data acquisition, analysis and interpretation; drafting and editing the manuscript.
All authors have read and approved the final version of the manuscript of the article. All authors agree to bear responsibility for all aspects of the study to ensure proper consideration and resolution of all possible issues related to the correctness and reliability of any part of the work.
Funding source. This study was not supported by any external sources of funding.
Disclosure competing interests. The authors declare that they have no competing interests.
Ethics approval. Not applicable.
Consent for publication. Not required.
About the authors
Pavel V. Fedonov
Federal Center for Traumatology, Orthopedics and Arthroplasty
Author for correspondence.
Email: mr_vulfgar@mail.ru
ORCID iD: 0000-0003-2833-235X
Россия, Cheboksary
Dmitry V. Kovalev
Federal Center for Traumatology, Orthopedics and Arthroplasty
Email: kovalev@orthoscheb.ru
ORCID iD: 0000-0002-4011-6409
Россия, Cheboksary
Nikolai S. Nikolaev
Federal Center for Traumatology, Orthopedics and Arthroplasty; Chuvash State University named after I.N. Ulyanov
Email: nikolaevns@mail.ru
ORCID iD: 0000-0002-1560-470X
Dr. Sci. (Med.), Professor
Россия, Cheboksary; CheboksaryAnatoly S. Mikhailov
Federal Center for Traumatology, Orthopedics and Arthroplasty
Email: orelwolf@gmail.com
ORCID iD: 0000-0003-0533-0570
Россия, Cheboksary
References
- Котельников Г.П., Колсанов А.В., Николаенко А.Н., Згирский Д.О., Дороганов С.О. Анализ биомеханики проксимального межфалангового сустава после эндопротезирования. Гений ортопедии. 2023;29(5): 468-474. doi: 10.18019/1028-4427-2023-29-5-468-474. Kotelnikov G.P., Kolsanov A.V., Nikolaenko A.N., Zgirskii D.O., Doroganov S.O. Biomechanics of the proximal interphalangeal joint after total joint replacement. Genij Ortopedii. 2023;29(5):468-474. (In Russian). doi: 10.18019/1028-4427-2023-29-5-468-474.
- Hensler S., Behm P., Wehrli M., Marks M., Ferguson S.J., Herren D.B. et al. Lateral stability in healthy proximal interphalangeal joints versus surface replacement and silicone arthroplasty: Results of a three-dimensional motion analysis study. Hand Surg Rehabil. 2020;39(4):296-301. doi: 10.1016/j.hansur.2020.02.013.
- Matter-Parrat V. Proximal interphalangeal joint prosthetic arthroplasty. Hand Surg Rehabil. 2023;42(3):184-193. doi: 10.1016/j.hansur.2023.02.001.
- Welford P., Blencowe N.S., Pardington E., Jones C.S., Blazeby J.M., Main B.G. Systematic review of the introduction, early phase study and evaluation of pyrocarbon proximal interphalangeal joint arthroplasty. PLoS One. 2021;16(10):e0257497. doi: 10.1371/journal.pone.0257497.
- Николаенко А.Н., Иванов В.В., Згирский Д.О., Дороганов С.О., Исайкин П.Ю., Кулебакина Я.А. Эндопротезирование проксимального межфалангового сустава. Обзор литературы. 2022;23:748-766. Режим доступа: https://www.medline.ru/public/art/tom23/art45.html. Nikolaenko A., Ivanov V., Zgirsky D., Doroganov S., Isaikin P., Kulebakina Y. Endoprosthetics of the proximal interphalangeal joint. Literature review. 2022;23: 748-766. (In Russian). Available from: https://www.medline.ru/public/art/tom23/art45.html.
- Raducha J.E., Weiss A.C. Proximal Interphalangeal Joint Arthroplasty for Fracture. Hand Clin. 2023;39(4):575-586. doi: 10.1016/j.hcl.2023.06.004.
- Laurent R., El Rifai S., Loisel F., Lepage D., Obert L., Pluvy I. Functional evaluation following emergency arthroplasty of the proximal interphalangeal joint for complex fractures with silicone implant. Hand Surg Rehabil. 2020;39(5):423-430. doi: 10.1016/j.hansur.2020.05.003.
- Wu C., Drake M., Means R. Jr. Total Joint Arthroplasty of a Proximal Interphalangeal Joint with Proximal Metal Surface Replacement and Distal Hemi-Hamate Autograft: A Long-Term Follow-Up. J Hand Surg Glob Online. 2022;4(3):189-193. doi: 10.1016/j.jhsg.2022.02.002.
- Mora A.N., Earp B.E., Blazar P.E. Midterm Clinical and Radiographic Follow-Up of Pyrolytic Carbon PIP Arthroplasty. J Hand Surg Am. 2020;45(3):253.e1-253.e6. doi: 10.1016/j.jhsa.2019.06.008.
- Regas I., Pluvy I., Leroy M., Obert L., Bellemère P., Loisel F. Arthroplasty for destroyed proximal interphalangeal joint in hand trauma surgery: Silicone hinged NeuFlex® or gliding Tactys®? Hand Surg Rehabil. 2022;41(6):681-687. doi: 10.1016/j.hansur.2022.09.006.
- Forte A., Murray P. Osteoarthritis and Prosthetic Joints in the Hand. In: Plastic Surgery – Principles and Practice. 2022. p. 896-905. doi: 10.1016/B978-0-323-65381-7.00057-5.
- Федотов П.В., Ковалев Д.В., Михайлов А.С. Эндопротезирование проксимального межфалангового сустава кисти: современное состояние проблемы. Гений ортопедии. 2024;30(5):743-752. doi: 10.18019/1028-4427-2024-30-5-743-752. Fedotov P.V., Kovalev D.V., Mikhailov A.S. Arthroplasty of the proximal interphalangeal joint of the hand: the current state of the problem. Genij Ortopedii. 2024;30(5):743-752. (In Russian). doi: 10.18019/1028-4427-2024-30-5-743-752.
- Faulkner H., An V., Lawson R.D., Graham D.J., Sivakumar B.S. Proximal Interphalangeal Joint Arthrodesis Techniques: A Systematic Review. Hand (N Y). 2023;18(1):74-79. doi: 10.1177/1558944721998019.
- Hunag Y.C., Chang C.M., Huang S.F., Hong C.H., Lin C.L. Development and Biomechanical Evaluation of an Anatomical 3D Printing Modularized Proximal Inter-Phalangeal Joint Implant Based on the Computed Tomography Image Reconstructions. Int J Bioprint. 2022;8(3):579. doi: 10.18063/ijb.v8i3.579.
- Selig H.F., Schulz M., Pillukat T., Prommersberger K.J., van Schoonhoven J., Mühldorfer-Fodor M. Outcome of proximal interphalangeal joint replacement with pyrocarbon implants: a long-term longitudinal follow-up study. Arch Orthop Trauma Surg. 2020;140(11): 1847-1857. doi: 10.1007/s00402-020-03592-3.
- Uchiyama S., Cooney W.P. 3rd, Linscheid R.L., Niebur G., An K.N. Kinematics of the proximal interphalangeal joint of the finger after surface replacement. J Hand Surg Am. 2000;25(2):305-312. doi: 10.1067/jhsu.2000.jhsu25a0305.
- Boeckstyns M.E.H. My personal experience with arthroplasties in the hand and wrist over the past four decades. J Hand Surg Eur Vol. 2019;44(2):129-137. doi: 10.1177/1753193418817172.
- Richards T., Ingham L., Russell I., Newington D. The Long-term Results of Proximal Interphalangeal Joint Arthroplasty of the Osteoarthritic Index Finger. Hand (N Y). 2022;17(2):266-270. doi: 10.1177/1558944720921468.
- Wagner E.R., Barras L.A., Fort M.W., Robinson W., Rizzo M. Results of proximal interphalangeal arthroplasty: border digits versus middle digits. J Hand Surg Eur Vol. 2020;45(7):709-714. doi: 10.1177/1753193420926127.
- Milone M.T., Klifto C.S., Hacquebord J.H. Prosthetic Arthroplasty of Proximal Interphalangeal Joints for Treatment of Osteoarthritis and Posttraumatic Arthritis: Systematic Review and Meta-Analysis Comparing the Three Ulnar Digits With the Index Finger. Hand (N Y). 2019;14(5):658-663. doi: 10.1177/1558944718791186.
- Moran S.L., Rizzo M. Managing Difficult Problems in Small Joint Arthroplasty: Challenges, Complications, and Revisions. Hand Clin. 2023;39(3):307-320. doi: 10.1016/j.hcl.2023.02.006.
- Renfree K.J. Surgical approaches for proximal interphalangeal joint arthroplasty. Bone Joint J. 2022;104-B(12):1329-1333. doi: 10.1302/0301-620X.104B12.BJJ-2022-0946.
- Bodmer E., Marks M., Hensler S., Schindele S., Herren D.B. Comparison of outcomes of three surgical approaches for proximal interphalangeal joint arthroplasty using a surface-replacing implant. J Hand Surg Eur Vol. 2020;45(6):608-614. doi: 10.1177/1753193419891382.
- Lans J., Notermans B.J.W., Germawi L., Lee H., Jupiter J.B., Chen N.C. Factors Associated With Reoperation After Silicone Proximal Interphalangeal Joint Arthroplasty. Hand (N Y). 2021;16(4):461-466. doi: 10.1177/1558944719864453.
- Louvion E., Santos C., Samuel D. Rehabilitation after proximal interphalangeal joint replacement: A structured review of the literature. Hand Surg Rehabil. 2022;41(1):14-21. doi: 10.1016/j.hansur.2021.09.007.
- Sharma S., Ong J., Putti A. Proximal Interphalangeal Joint Arthroplasty Using the Wide-Awake Local Anesthesia No Tourniquet Technique. Hand (N Y). 2023;18(4):612-615. doi: 10.1177/15589447211063545.
- Notermans B.J.W., Teunissen J.S., Selles R.W., de Boer L.H.L.; Hand Wrist Study Group; van der Heijden BEPA. Type of Work and Preoperative Ability to Perform Work Affect Return to Usual Work Following Proximal Interphalangeal Joint Arthroplasty for Osteoarthritis. Hand (N Y). 2024;19(4): 648-655. doi: 10.1177/15589447221141485.
- Федотов П.В., Ковалев Д.В., Рыбаков С.Н. Оценка отдаленных результатов эндопротезирования проксимального межфалангового сустава кисти. Гений ортопедии. 2024;30(2):191-199. doi: 10.18019/1028-4427-2024-30-2-191-199. Fedotov P.V., Kovalev D.V., Rybakov S.N. The long-term results of proximal interphalangeal joint arthroplasty of the hand. Genij Ortopedii. 2024;30(2):191-199. (In Russian). doi: 10.18019/1028-4427-2024-30-2-191-199.
- Millrose M., Gesslein M., Ittermann T., Kim S., Vonderlind H.C., Ruettermann M. Arthrodesis of the proximal interphalangeal joint of the finger – a systematic review. EFORT Open Rev. 2022;7(1):49-58. doi: 10.1530/EOR-21-0102.
- Millrose M., Vonderlind H.C., Thannheimer A., Ittermann T., Rüther J., Willauschus M. et al. Arthrodesis of the Proximal Interphalangeal Joint of the Finger – A Biomechanical Study of Primary Stability. J Pers Med. 2023;13(3):465. doi: 10.3390/jpm13030465.
- Uhiara O., Hussain S., Deshmukh S. Plate-augmented tension band wiring for arthrodesis of the proximal interphalangeal and metacarpophalangeal joints: a case series. J Hand Surg Eur Vol. 2021;46(6):679-681. doi: 10.1177/1753193421991762.
- Xu J., Yong F.C., Lim C.W., Wong K.J.H., Teoh L.C. The impact of various simulated arthrodesis angles of the proximal interphalangeal joint of the ring and middle finger on grip strength. Arch Orthop Trauma Surg. 2022;142(4):701-705. doi: 10.1007/s00402-021-04317-w.
- Dimitrova P., Reger A., Prommersberger K.J., van Schoonhoven J., Mühldorfer-Fodor M. Effect of a single proximal interphalangeal Joint Fusion of the Index, Middle or Ring Finger on the Grip and Finger Force and Load Distribution in the Hand. Handchir Mikrochir Plast Chir. 2022;54(5):409-417. (In German). doi: 10.1055/a-1750-9586.
Supplementary files