Errors and complications in the surgical treatment of patients with distal radius fractures

Cover Page


Cite item

Full Text

Abstract

The purpose - to analyze errors and complications in surgical treatment of patients with distal radius fractures and to determine methods of its prevention. Material and methods. 203 patients (62 male and 141 female ones) with 204 distal radius fractures were treated using plate osteosynthesis. 105 patients were operated ear-lier than 1 month after the injury (I group), 98 - in 1 month or later after the injury (II group). The results of the treatment were assessed with morphometric and clinical indi-cators, scheme offered by the authors and DASH questionnaire. Results. 88,68% of positive results in I group and 72,45% in II group were ob-served in a year after the operation. The frequency of complications on application of palmar surgical approach was 4,72% in I group and 17,35% (р=0,0001) in II group. The rate of hardware removal reduced to 6,6% in I group and to 11,22% - in II group of patients (р=0,245) that is in 3,3-4,75 times lower than the data given in the literature.

About the authors

O. M. Semenkin

Samara State Medical University; Kalinin Regional Clinical Hospital

Author for correspondence.
Email: olegsemenkin63@yandex.ru
Russian Federation

S. N. Izmalkov

Samara State Medical University

Email: noemail@neicon.ru
Russian Federation

References

  1. Голубев И.О., Крупаткин А.И, Максимов А.А., Меркулов М.В., Бушуев О.М., Ширяева Г.Н. и др. Хирургическое лечение неправильно сросшихся переломов дистального метаэпифиза лучевой кости. Вестник травматологии и ортопедии. 2013; (3): 51-59.
  2. Измалков С.Н., Семенкин О.М. Современные подходы к лечению больных с осложненными переломами лучевой кости в «типичном месте»: методические рекомендации. Самара: СамГМУ; 2008. 30 с.
  3. Котельников Г.П., Шпигель А.С. Доказательная медицина. Научно обоснованная медицинская практика: монография. Изд. 2-е перераб. и доп. М.: ГЭОТАР-Медиа, 2012. 242 с.
  4. Семенкин О.М., Измалков С.Н., Нефедов С.А. Критерии нестабильности и их влияние на клинико-рентгенометрические показатели при переломах дистального метаэпифиза лучевой кости. Вестник экспериментальной и клинической хирургии. 2014; VII (1): 47-53.
  5. Al-Rashid M., Theivendran K., Craigen M.A. Delayed rupture of the extensor tendon secondary to the use of palmar locking compression plates for distal radial fractures. J. Bone Joint Surg (Br). 2006; 88: 1610-1612.
  6. Arora R., Lutz M., Zimmermann R., Krappinger D., Gabl M., Pechlaner S. Grenzen der palmaren winkelstabilen Plattenosteosynthese bei instabilen distalen Radiusfrakturen. Handchir. Mikrochir. Plast. Chir. 2007; 39: 34-41.
  7. Casaletto J.A., Machin D., Leung R., Brown D.J. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J. Hand Surg. (E). 2009; 34(4): 471-474.
  8. Cross A.W., Schmidt C.C. Flexor tendon injuries following locked volar plating of distal radius fractures. J. Hand Surg. (A). 2008; 33(2): 164-167.
  9. Doenicke T., Lenz M., Friedel R., Hofmann G.O. The tangential fluoroscopic view of the dorsal distal radius outline - an intraoperative radiographic imaging to detect dorsally prominent screws during palmar plating of distal radius fractures. In: Abstracts of XIV Congress of the Federation of the European Societies for Surgery of the Hand. Poznań, 2009. Paper 67. p. 123.
  10. Drobetz H., Kutscha-Lissberg E. Osteosynthesis of distal radius fractures with a volar locking screw plate system. Int. Orthop. 2003; 27: 1-6.
  11. El-Karef E. Staged reconstruction for malunited fractures of the distal radius. J. Hand Surg. (Br). 2005; 30: 73.
  12. Esenvein P., Sonderegger J., Ellenrieder B., Gruenert J. Complications following palmar plate fixation of distal radius fractures: A review of 665 cases. J. Hand Surg. (E). 2011; 36 (1):S106.
  13. Herdrich S., Bauer J., Pichl J., Hoffmann R. Management of complex, intraarticular distal radius fractures with open reduction and internal fixation with dorsal locking plates. In: Abstract Book 10th EFORT Congress. Vienna, 2009. p. 1374.
  14. Lafontaine M., Hardy D., Delince P.H. Stability assessment of distal radius fractures. Injury. 1989; 20: 208-210.
  15. Lattmann T., Dietrich M., Meier C., Kilgus M., Platz A. Comparison of 2 surgical approaches for volar locking plate osteosynthesis of the distal radius. J. Hand Surg. (A). 2008; 33(7): 1135-1143.
  16. Mignemi M.E., Byram I.R., Wolfe C.C., Fan K.-H., Koehler E.A. et al. Radiographic outcomes of volar locked plating for distal radius fractures. J. Hand Surg. (A). 2013; 38(1): 40-48.
  17. Paksima N., Tejwani N.C., McLaurin T.M., Walsh M., Lawler E.A., Egol K.A. Early complications of distal radius fractures: operative and nonoperative treatment In: Annual Meeting of American Academy of Orthopaedic Surgeons: Proceedings. San Diego, 2007. Paper 409. p. 510.
  18. Prommersberger K.-J., Moossavi S., Lanz U. Ergebnisse der Korrekturosteotomie fehlverheilter Extensionsfrakturen der Speiche an typischer Stelle. Handchir. Mikrochir. Plast Chir. 1999; 4: 234-240.
  19. Sahu A., Batra S., Charalambos C., Ravenscroft M. Reoperation for metalwork complications following the use of volar locking plates for distal radius fractures; experience of a general trauma unit in UK In: Abstract Book 10th EFORT Congress. Vienna, 2009. F. 167.
  20. Sakhaji M., Grönewold U., Klonz A., Reilmann H. Ergebnisse nach palmarer Plattenosteosynthese mit der winkelstabilen T-Platte bei 100 distalen Radiusfrakturen. Unfallchirurgie. 2003; 106: 272-280.
  21. Soong M., van Leerdam R., Guitton T.G., Got C., Katarincic J., Ring D. Fracture of the distal radius: risk factors for complications after locked volar plate fixation J Hand Surg (A). 2011; 36(1): 3-9.
  22. Stern P.J. Complications of plate fixation of the distal radius In: Annual Meeting of American Academy of Orthopaedic Surgeons: Proceedings. San Diego, 2007. p. 161.
  23. Thielke S.H., Spors-Schrödter L., Wasgner T. et al. Winkelstabile Plattenosteosynthese am distalen Radius: Lösung einer Problemfraktur? Akt. Traumatol. 2002; 32: 245-250.
  24. Weihrauch M., Bickert B., Germann G., Sauerbier M. Funktionelle Ergebnisse nach Radiuskorrekturosteotomie. Unfallchirurg. 2006; 109: 93-100.
  25. Windolf J., Hakimi M., Schädel-Höpfner M. Ergebnisse der palmaren winkelstabilen Plattenosteosynthese am distalen Radius. Trauma Berufskrankh. 2008; 10(2): 236-240.
  26. Yu Y.R., Makhni M.C., Tabrizi S., Rozental T.D. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg (A). 2011; 36(7): 1135-1141.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2014



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies