全文:
详细
Relevance. The correct implantation of acetabular component in total hip arthroplasty is an important factor for obtaining good outcomes and long-term survival of the prosthesis. The anteversion angle is one of the significant indicators for the three-dimensional orientation of the cup. The purpose of the study — to develope the method of calculating the anteversion angle of the acetabular component using postoperative anteroposterior radiographs of the hip and pelvis.
The method. The authors used the projection ellipse formed by the opening of the prosthesis cup on the radiograph centered on the hip joint to calculate the desired value. The ratio sine of projectional diameter of the ellipse to its true diameter is a mathematical formula for finding the angle of anteversion. The comparison of the calculated index on anteroposterior radiographs centered on the hip joint and on the pelvis is necessary to identify the distinction between anteversion and retroversion of the acetabular component. In negative anteversion, or retroversion, the projectional diameter on the pelvic radiograph is larger than on the radiograph focused on the hip joint.
Conclusion. Measuring of anteversion angle of acetabular component on postoperative radiograph allows to gain an optimal orientation of acetabular component which decreases postoperative complications rate. X-rays of any scale can be used for measurements while the ratio but not the absolute value of measured diameters is important for the result.
作者简介
S. Dianov
Astrakhan State Medical University
Email: fake@neicon.ru
Sergei V. Dianov — Dr. Sci. (Med.), Professor, Head of the Chair of Traumatology and Orthopaedics.
121, Bakinskaya ul., Astrakhan, 414000 俄罗斯联邦S. Domovitov
Podolsk City Clinical Hospital
编辑信件的主要联系方式.
Email: doctor1981@rambler.ru
Stepan V. Domovitov — Cand. Sci. (Med.), Orthopaedics Surgeon.
38, Kirova ul., Podolsk, 142100
俄罗斯联邦A. Zhuzhnev
Yeysk Central District Hospital
Email: fake@neicon.ru
Aleksandr V. Zhuzhnev — Orthopaedics Surgeon.
145, Engelsa ul., Yeysk, 353690
俄罗斯联邦D. Shikunov
State Research Center Burnasyan Federal Medical Biophysical Center
Email: fake@neicon.ru
Dmitrii A. Shikunov — Roentgenologist.
23, Marshala Novikova ul., Moscow, 123098
俄罗斯联邦A. Semenov
Guzhvin Boarding School for Gifted Children
Email: fake@neicon.ru
Aleksei L. Semenov — teacher.
103, ul. Bezzhonova, Astrakhan, 414018
俄罗斯联邦参考
- Павлов В.В., Прохоренко В.М. Вывихи бедренного компонента эндопротеза тазобедренного сустава: определение пространственного взаиморасположения компонентов. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2016;(3):5-10. Pavlov V.V., Prokhorenko V.M. [Dislocations of the femoral component of hip implant: determination of spatial relative position of components. Vestnik travmatologii i ortopedii imeni N.N. Priorova [Reporter of Traumatology and Orthopedics named Priorov]. 2016;(3):5-10. (in Russian).
- Тихилов Р.М., Шубняков И.И., Коваленко А.Н., Тотоев З.А., Лю Б., Билык С.С. Структура ранних ревизий эндопротезирования тазобедренного сустава. Травматология и ортопедия России. 2014;(2):5-13. doi: 10.21823/2311-2905-2014-0-2-5-13. Tikhilov R.M., Shubnyakov I.I., Kovalenko A.N., Totoyev Z.A., Lyu B., Bilyk S.S. [The structure of early revisions after hip replacement]. Travmatologiya i ortopediya Rossii [Traumatology and Orthopedics of Russia]. 2014;(2): 5-13. (in Russian). doi: 10.21823/2311-2905-2014-0-2-5-13.
- Шильников В.А., Байбородов А.Б., Денисов А.О., Ефимов Н.Н. Двойная мобильность ацетабулярного компонента как способ профилактики вывиха головки эндопротеза тазобедренного сустава. Травматология и ортопедия России. 2016;22(4): 107-113. doi: 10.21823/2311-2905-2016-22-4-107-113. Shilnikov V.A., Baiborodov A.B., Denisov A.O., Efimov N.N. [Dual mobility acetabular component as a way to prevent head dislocation of the hip]. Travmatologiya i Ortopediya Rossii [Traumatology and Orthopedics of Russia]. 2016;22(4):107-113. (in Russian). doi: 10.21823/2311-2905-2016-22-4-107-113.
- Шубняков И.И., Бояров А.А., Тихилов Р.М., Денисов А.О., Ефимов Н.Н. Влияние позиционирования вертлужного компонента эндопротеза на стабильность тазобедренного сустава. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2017;(2):22-31. Shubnyakov I.I., Boyarov A.A., Tikhilov R.M., Denisov A.O., Efimov N.N. [Influence of implant acetabular component orientation on hip stability]. Vestnik travmatologii i ortopedii imeni N.N. Priorova [Reporter of Traumatology and Orthopedics named Priorov]. 2017;(2):22-31. (in Russian).
- Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties. J Bone Joint SurgAm. 1978;60(2):217-220.
- Liaw C.K., Hou S.M., Yang R.S., WuT.Y., Fuh C.S. A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs. Clin Orthop Relat Res. 2006;451:134-139.
- Widmer K.H. A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004;19(3):387-390.
- Woo R.Y., Morrey B.F. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982;64(9):1295-1306.
- Jolles B.M., Zangger P., Leyvraz P.F. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty. 2002;17(3):282-288.
- Arai N., Nakamura S., Matsushita T., Suzuki S. Minimal radiation dose computed tomography for measurement of cup orientation in total hip arthroplasty. J Arthroplasty. 2010;25(2):263-267. doi: 10.1016/j.arth.2009.01.020.
- Ybinger T., Kumpan W., Hoffart H.E., Muschalik B., Bullmann W., Zweymüller K. Accuracy of navigationassisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007;22(6):812-817. doi: 10.1016/j.arth.2006.10.001.
- Fabeck L., Farrokh D., Tolley M., Descamps P.Y., Gebhart M., Delincé P. A method to measure acetabular cup anteversion after total hip replacement. Acta Orthop Belg. 1999;65(4):485-491.