USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT)

封面


如何引用文章

全文:

详细

Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC). CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

作者简介

R. Tikhilov

Vreden Russian Research Institute of Traumatology and Orthopedics, Mechnikov North-Western State Medical University

Email: fake@neicon.ru
director 俄罗斯联邦

I. Shubnyakov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru
Academic Secretary 俄罗斯联邦

A. Kovalenko

Vreden Russian Research Institute of Traumatology and Orthopedics

编辑信件的主要联系方式.
Email: tonnchik@ya.ru
researcher 俄罗斯联邦

C. Bilyk

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru
researcher 俄罗斯联邦

A. Tsybin

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru
researcher 俄罗斯联邦

A. Denisov

Vreden Russian Research Institute of Traumatology and Orthopedics

Email: fake@neicon.ru
head of scientific department 俄罗斯联邦

G. Dmitrevich

Saint Petersburg Electrotechnical University

Email: fake@neicon.ru
professor of computer-aided design system department 俄罗斯联邦

P. Vopilovsky

Peter the Great Saint-Petersburg Polytechnic University

Email: fake@neicon.ru
director of NTK «Machine Technology» 俄罗斯联邦

参考

  1. Дианов С.В. Восстановление опорности вертлужной впадины при сложном первичном и ревизионном эндопротезировании. В кн.: Травматология и ортопедия в России: традиции и инновации. Саратов; 2015. С. 92-94.
  2. Мурылев В.Ю., Петров Н.В., Рукин Я.А., Елизаров П.М., Калашник А.Д. Ревизионное эндопротезирование вертлужного компонента эндопротеза тазобедренного сустава. Кафедра травматологии и ортопедии. 2012; (1):20-25.
  3. Тихилов Р.М., Шубняков И.И., Коваленко А.Н., Черный А.Ж., Муравьева Ю.В., Гончаров М.Ю. Данные регистра эндопротезирования тазобедренного сустава РНИИТО им. Р.Р. Вредена за 2007–2012 годы. Травматология и ортопедия России. 2013; (3):167-190.
  4. Травматизм, ортопедическая заболеваемость, состояние травматолого-ртопедической помощи населению России в 2008 году. М.: ЦИТО; 2009.
  5. Травматизм, ортопедическая заболеваемость, состояние травматолого-ортопедической помощи населению России в 2014 году. М.: ЦИТО; 2015.
  6. Abdelnasser M.K., Klenke F.M., Whitlock P., Khalil A.M., Khalifa Y.E., Ali H.M., Siebenrock K.A. Management of pelvic discontinuity in revision total hip arthroplasty: a review of the literature. Hip Int. 2015; 25(2):120-126.
  7. Amenabar T., Rahman W.A., Hetaimish B.M., Kuzyk P.R., Safir O.A., Gross A.E. Promising mid-term results with a cup-cage construct for large acetabular defects and pelvic discontinuity. Clin Orthop Relat Res. 2016;474(2): 408-414.
  8. Berry D.J., Lewallen D.G., Hanssen A.D., Cabanela M.E. Pelvic discontinuity in revision total hip arthroplasty. J Bone Joint Surg Am. 1999; 81(12):1692-1702.
  9. Berry D.J. Antiprotrusio cages for acetabular revision. Clin Orthop Relat Res. 2004; 420:106-112.
  10. D’Antonio J.A., Capello W.N., Borden L.S., Bargar W.L., Bierbaum B.F., Boettcher W.G., Steinberg M.E., Stulberg S.D., Wedge J.H. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989; 243:126-137.
  11. DeBoer D.K., Christie M.J., Brinson M.F., Morrison J.C. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007; 89(4):835-840.
  12. Eggli S., Müller C., Ganz R. Revision surgery in pelvic discontinuity: an analysis of seven patients. Clin Orthop Relat Res. 2002; (398):136-145.
  13. Goodman S., Saastamoinen H., Shasha N., Gross A. Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplasty. 2004; 19(4):436-446.
  14. Jain S., Grogan R.J., Giannoudis P.V. Options for managing severe acetabular bone loss in revision hip arthroplasty. A systematic review. Hip Int. 2014; 24(2):109-22.
  15. Paprosky W., Sporer S., O’Rourke M.R. The treatment of pelvic discontinuity with acetabular cages. Clin Orthop Relat Res. 2006; 453(453):183-187.
  16. Paprosky W.G., Perona P.G., Lawrence J.M. Acetabular defect classification and surgical reconstruction in revision arthroplasty: a 6-year follow-up evaluation. J rthroplasty. 1994; 9:33-44.
  17. Paprosky W.G., Sporer S.S., Murphy B.P. Addressing severe bone deficiency: what a cage will not do. J Arthroplasty. 2007; 22(4 Suppl 1):111-115.
  18. Regis D., Sandri A., Bonetti I., Bortolami O., Bartolozzi P. A minimum of 10-year follow-up of the Burch-Schneider cage and bulk allografts for the revision of pelvic discontinuity. J Arthroplasty. 2012; 27(6):1057-1063, e1.
  19. Symeonides P.P., Petsatodes G.E., Pournaras J.D., Kapetanos G.A., Christodoulou A.G., Marougiannis D.J. The effectiveness of the Burch-Schneider antiprotrusio cage for acetabular bone deficiency: five to twentyone years’ follow-up. J Arthroplasty. 2009; 24(2): 168-174.
  20. Taunton M.J., Fehring T.K., Edwards P., Bernasek T., Holt G.E., Christie M.J. Pelvic discontinuity treated with custom triflange component: a reliable option. Clin Orthop Relat Res. 2012; 470(2):428-434.

补充文件

附件文件
动作
1. JATS XML

版权所有 © , 2016



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


##common.cookie##