Version of the subastragalar arthrodesis
- Authors: Tikhilov RM1, Voronkevich IA1, Malygin RV1, Lasunsky SA1
-
Affiliations:
- Issue: No 2 (2009)
- Pages: 117-122
- Section: Modern technologies in traumatology and orthopedics
- Submitted: 19.07.2022
- Published: 15.06.2009
- URL: https://journal.rniito.org/jour/article/view/1921
- DOI: https://doi.org/10.17816/2311-2905-1921
- ID: 1921
Cite item
Full Text
Abstract
A new internal fixator The Plate for osteosynthesis of periprithetic femoral fractures is described and illustrated in compare with conventional straight AO-ASIF femoral LCP. This new plate is simple, reliable and AO-ASIF compatible metal implant designed for fractures around or below the stable endoprothetic stem i.e. for В1 and C types according the Vancouver classification by C.P. Duncan and B.A. Marsi. The periprothetic plate allows to fix these types of fracture more rigidly than other internal fixators and thus improve final functional results
Keywords
About the authors
R M Tikhilov
I A Voronkevich
Email: dr_voronkevich@inbox.ru
R V Malygin
S A Lasunsky
References
- Неверов, В.А. Ревизионное эндопротезирование тазобедренного сустава / В.А. Неверов, С.М. Закари. - СПб. : Образование, 1997. - 112 с.
- Способы лечения перипротезных переломов бедра / М.В. Белов [и др.] // Современные технологии в травматологии, ортопедии: ошибки и осложнения - профилактика и лечение : тезисы международного конгресса. - Москва, 2004. - С. 56.
- Сравнение эффективности способов лечения перипротезных переломов бедра / М.В. Белов [и др.] // Травматология и ортопедия России. - 2006. - № 3. - С. 33-36.
- Шершер, Я.И. Компрессионный остеосинтез аппаратом Илизарова при переломе бедренной кости после тотального эндопротезирования тазобедренного сустава / Я.И. Шершер, Л.Н. Маторин // Ортопедия, травматология. - 1986. - № 11. - С. 64-65.
- Duncan, C.P. Fractures of the femur after hip replacement / C.P. Duncan, B.A. Marsi // Instr. Course Lect. - 1995. - № 44. - P. 293-304.
- Fitzgerald, R.H. The un-cemented total hip arthroplasty - intraoperative femoral fractures / R.H. Fitzgerald, G.W. Brindley, B.F. Kavanagh // J. Clin. Orthop. - 1998. - Vol. 235. - P. 61-66.
- Fracture of the ipsilateral femur in patients with total hip replacement. / J.E. Johansson, R. McBroom, T.W. Barrington, J.A. Hunter // J. Bone Joint. Surg. Am. - 1981. - Vol. 63. - P. 1435-1442.
- Mallory, T.H. Intraoperative femoral fractures associated with cementless total hip arthroplasty / T.H. Mallory, T.J. Kraus, B.K. Vaughn // J. Orthopedics. - 1989. - Vol. 12. - P. 231-239.
- McElfresh, E.C. Femoral and pelvic fractures after total hip arthroplasty / E.C. McElfresh, M.B. Coventry // J. Bone Joint. Surg. Am. - 1974. -Vol. 56. - P. 483-492.
- Schwartz, J.T. Femoral fracture during non- cemented total hip arthroplasty. / J.T. Schwartz, J.G. Mayer, C.A. Engh // J. Bone Joint. Surg. Am. - 1989. - Vol. 71. - P. 1135-1142.
- Struchin, S.A. Femoral shaft fracture in porous and press fit total hip arthroplasty. / S.A. Struchin // Orthop. Rev. - 1990. - Vol. 19. - P. 153-159.
- Taylor, M.H. Intraoperative femur fractures during total hip replacement. / M.H. Taylor , J.P. Harvey // J. Clin. Orthop. - 1978. - Vol. 137. - P. 96-103.