DUAL MOBILITY ACETABULAR COMPONENT AS A WAY TO PREVENT HEAD DISLOCATION OF THE HIP

封面


如何引用文章

全文:

详细

Prevention of femoral head dislocation is becoming one of the most important tasks in view of increased number of total hip replacement procedures throughout the world. The purpose of the present work is to acquaint the surgeons with possibilities and the first experience of dual mobility acetabular component application as the most up-to-date solution to prevent dislocation of the femoral head in primary or revision arthroplasties. The paper is based on the literature data and presents a critical analysis of the causes of femoral head dislocation during hip replacement. The authors considered historical aspects and the first outcomes of dual mobility use in the European and Western countries, as well as own positive clinical experience with dual mobility system during a study of 36 patients with an increased risk of femoral head dislocation.

作者简介

V. Shilnikov

Vreden Russian Research Institute of Traumatology and Orthopedics
8, ul. Akad. Baykova, St. Petersburg, 195427, Russia

编辑信件的主要联系方式.
Email: med-03@yandex.ru
Dr. Sci. (Med) the Head of department N 11 俄罗斯联邦

A. Baiborodov

Vreden Russian Research Institute of Traumatology and Orthopedics
8, ul. Akad. Baykova, St. Petersburg, 195427, Russia

Email: med-03@yandex.ru
orthopedic surgeon, department N 11 俄罗斯联邦

A. Denisov

Vreden Russian Research Institute of Traumatology and Orthopedics
8, ul. Akad. Baykova, St. Petersburg, 195427, Russia

Email: med-03@yandex.ru
Cand. Sci. (Med), Academic Secretary, Head of Hip Pathology Department 俄罗斯联邦

N. Efimov

Vreden Russian Research Institute of Traumatology and Orthopedics
8, ul. Akad. Baykova, St. Petersburg, 195427, Russia

Email: med-03@yandex.ru
Graduate Student 俄罗斯联邦

参考

  1. Кавалерский Г.М., Мурылев В.Ю., Рубин Г.Г., Рукин Я.А., Елизаров П.М., Музыченков А.В. Эндопротезирование тазобедренного сустава у пациентов с ложными суставами шейки бедренной кости. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2016;(1):21-25.
  2. Ключевский В.В., Даниляк В.В., Белов М.В., Гильфанов С.И., Конев Д.Е., Ключевский И.В., Молодов М.А. Вывихи после тотального замещения тазобедренного сустава: факторы риска, способы лечения. Травматология и ортопедия России. 2009;(3):136-138.
  3. Руководство по хирургии тазобедренного сустава / под ред. Р.М. Тихилова, И.И. Шубнякова. СПб. : РНИИТО им. Р.Р. Вредена; 2014. Т. 2. 356 с.
  4. Тихилов Р.М., Шубняков И.И., Коваленко А.И., Цыбин А.В., Семетковский А.В., Карпухин А.С., Башинский О.А. Современные тенденции в ортопедии: ревизии вертлужного и бедренного компонентов. Травматология и ортопедия России. 2012;(4):5-16.
  5. Тихилов Р.М., Шубняков И.И., Коваленко А.Н., Черный А.Ж., Муравьева Ю.В., Гончаров М.Ю. Данные регистра эндопротезирования тазобедренного сустава РНИИТО им. Р.Р. Вредена за 2007-2012 годы. Травматология и ортопедия России. 2013;(3):167-190.
  6. Тихилов Р.М., Шубняков И.И., Коваленко А.Н., Тотоев З.А., Лю Б., Билык С.С. Структура ранних ревизий эндопротезирования тазобедренного сустава. Травматология и ортопедия России. 2014;(2):5-13.
  7. Adam P., Farizon F., Fessy M.H. Dual articulation retentive ace- tabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Rev Chir Orthop. 2005;91:627-636.
  8. Adam P., Philippe R., Ehlinger M., Roche O., Bonnomet F., Molé D., Fessy M.H. Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res. 2012;98:296-300. doi: 10.1016/j.otsr.2012.01.005.
  9. Alberton G.M., High W.A., Morrey B.F. Dislocation after revision total hip arthroplasty : an analysis of risk factors and treatment options. J Bone Joint Surg Am. 2002;84-A:1788-1792.
  10. Bayley N., Khan H., Grosso P., Hupel T., Stevens D., Snider M., Schemitsch E., Kuzyk P. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthop Relat Res. 2015;473:477-84. doi: 10.1007/s11999-014-3824-2.
  11. Blake S.M., Kitson J., Howell J.R., Gie G.A., Cox P.J. Constrained total hip arthroplasty in a paediatric patient with cerebral palsy and painful dislocation of the hip. A case report. J Bone Joint Surg Br. 2006;88(5):655-657. doi: 10.1302/0301-620X.88B5.17206.
  12. Blomfeldt R., Törnkvist H., Ponzer S., Söderqvist A., Tidermark J. Comparison of internal fixation with total hip replacement for displaced femoral neck fractures. Randomized, controlled trial performed at four years. J Bone Joint Surg Am. 2005;87:1680-1688. doi: 10.2106/JBJS.D.02655.
  13. Bozic K.J., Kurtz S.M., Lau E., Ong K., Vail T.P., Berry D.J. The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am. 2009;91:128-133. doi: 10.2106/JBJS.H.00155.
  14. Callaghan J.J., Bracha P., Liu S.S., Piyaworakhun S., Goetz D.D., Johnston R.C. Survivorship of a Charnley total hip arthroplasty. A concise follow-up, at a minimum of thirty-five years, of previous reports. J Bone Joint Surg Am. 2009;91(11):2617-2621. doi: 10.2106/JBJS.H.01201.
  15. Caton J., Prudhon J.L. Over 25 years survival after Charnley‘s total hip arthroplasty. Int Orthop. 2011; 35(2):185. doi: 10.1007/s00264-010-1197-z.
  16. Garbuz D.S., Masri B.A., Duncan C.P., Greidanus N.V., Bohm E.R., Petrak M.J., Della Valle C.J., Gross A.E. The Frank Stinchfield Award. Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial? Clin Orthop Relat Res. 2012;470(2):351-356. doi: 10.1007/s11999-011-2146-x.
  17. Gioe T.J. Dislocation following revision total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2002;31:225-227.
  18. Guyen O., Pibarot V., Vaz G., Chevillotte C., BéjuiHugues J. Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res. 2009;467:465-472.
  19. Farizon F., de Lavison R., Azoulai J.J., Bousquet G. Results with a cementless alumina-coated cup with dual mobility. Int Orthop. 1998;22:219-224.
  20. Hamadouche M., Biau D.J., Huten D., Musset T., Gaucher F. The use of a cemented dual mobility socket to treat recurrent dislocation. Clin Orthop Relat Res. 2010;468:3248-3254. doi: 10.1007/s11999-010-1404-7.
  21. Iorio R., Healy W.L., Lemos D.W., Appleby D., Lucchesi C.A., Saleh K.J. Displaced femoral neck fractures in the elderly: outcomes and cost effectiveness. Clin Orthop Relat Res. 2001;(383):229-242.
  22. Langlais F.L., Ropars M., Gaucher F., Musset T., Chaix O. Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop Relat Res. 2008;466:389-395. doi: 10.1007/s11999-007-0047-9.
  23. Lecuire F., Benareau I., Rubini J., Basso M. Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop. 2004;90:249-255.
  24. McMinn D.J., Daniel J., Ziaee H., Pradhan C. Indications and results of hip resurfacing. Int Orthop. 2011;35(2): 231-237. doi: 10.1007/s00264-010-1148-8.
  25. Patel P.D., Potts A., Froimson M.I. The dislocating hip arthroplasty: prevention and treatment. J Arthroplasty. 2007;22:86-90. doi: 10.1016/j.arth.2006.12.111.
  26. Philippot R., Farizon F., Camilleri J.P., Boyer B., Derhi G., Bonnan J., Fessy M.H., Lecuire F. Survival of cementless dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot. 2008;94(8): e23-27. doi: 10.1016/j.rco.2007.10.013.
  27. Philippeau J.M., Durand J.M., Carret J.P., Leclercq S., Waast D., Gouin F. Dual mobility design use in preventing total hip replacement dislocation following tumor resection. Orthop Traumatol Surg Res. 2010;96:2-8. doi: 10.1016/j.rcot.2009.12.011.
  28. Prudhon J.L., Ferreira A., Verdier R. Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. Int Orthop. 2013;37(12):2345-2350. doi: 10.1007/s00264-013-2067-2.
  29. Raphael B.S., Dines J.S., Akerman M., Root L. Longterm followup of total hip arthroplasty in patients with cerebral palsy. Clin Orthop Relat Res. 2010;468:1845-1854. doi: 10.1007/s11999-009-1167-1.
  30. Sanchez-Sotelo J., Haidukewych G.J., Boberg C.J. Hospital cost of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2006;88:290-294. doi: 10.2106/JBJS.D.02799.
  31. Sanders R.J., Swierstra B.A., Goosen J.H. The use of a dual-mobility concept in total hip arthroplasty patients with spastic disorders: no dislocations in a series of ten cases at midterm follow-up. Arch Orthop Trauma Surg. 2013;133(7):1011-1016. doi: 10.1007/s00402-013-1759-9.
  32. Schairer W.W., Sing D.C., Vail T.P., Bozic K.J. Causes and frequency of unplanned hospital readmission after total hip arthroplasty. Clin Orthop Relat Res. 2014;472(2):464-470. doi: 10.1007/s11999-013-3121-5.
  33. Schroeder K., Hauck C., Wiedenhöfer B., Braatz F., Aldinger P.R. Long-term results of hip arthroplasty in ambulatory patients with cerebral palsy. Int Orthop. 2010;34:335-339. doi: 10.1007/s00264-009-0771-8.
  34. Stroh A., Naziri Q., Johnson A.J., Mont M.A. Dualmobility bearings: a review of the literature. Expert Rev Med Devices. 2012;9(1):23-31. doi: 10.1586/ERD.11.57.
  35. Sutphen S.A., MacLaughlin L.H., Madsen A.A., Russell J.H., McShane M.A. Prevalence of pseudotumor in patients after metal-on-metal hip arthroplasty evaluated with metal ion analysis and MARS-MRI. J Arthroplasty. 2016;31(1): 260-263. doi: 10.1016/j.arth.2015.07.011.
  36. Tarasevicius S., Busevicius M., Robertsson O., Wingstrand H. Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord. 2010;11:175. doi: 10.1186/1471-2474-11-175.

补充文件

附件文件
动作
1. JATS XML

版权所有 © , 2016



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


##common.cookie##