Intramedullary osteosynthesis of A1 type tibial fractures
- 作者: Litvinov II1, Razankov AG1
-
隶属关系:
- 期: 编号 3 (2009)
- 页面: 59-63
- 栏目: Experience exchange
- ##submission.dateSubmitted##: 19.07.2022
- ##submission.datePublished##: 15.09.2009
- URL: https://journal.rniito.org/jour/article/view/1861
- DOI: https://doi.org/10.17816/2311-2905-1861
- ID: 1861
如何引用文章
全文:
详细
Authors analyzed results of osteosynthesis by locking and not-locking nails in treatment of 64 patients with diaphyseal extra-isthmal A1 type tibial fractures. Patients were divided into two clinical groups. The first group consisted of 20 patients with juxta-isthmal fractures, the second - 44 patients with juxta-metaphyseal fractures. The obtained data show that the use of locking nails and rectangular section nails produced good results at juxta-isthmal fractures. In cases of juxta-metaphyseal fracture the use of rectangular section nails was associated with a greater risk of complications compared to locking nails.
参考
- Литвинов, И.И. Внутренний остеосинтез закрытых диафизарных переломов бедренной и большеберцовой костей : дис. …д-ра. мед. наук / Литвинов Игорь Иванович. - Ярославль, 2005. - 427 с.
- Johner, R. Classification of tibial shaft fractures and correlation with results after rigid internal fixation / R. Johner, O. Wruhs // Clin. Orthop. - 1983. - N 178. - P. 7-25.
- Müller, C.A. Intramedullary nailing of the tibia: Current status of primary unreamed nailing. Part 1: Results for closed fractures / C.A. Müller, P. Strohm, Ph. Morakis, U. Pfister // Injury. - 1999. - Vol. 30, N 3. - P. 39-43.