Vliyanie tsementnogo i bestsementnogoendoprotezirovaniya krupnykh sustavov na sistemnyyimmunnyy otvet

Abstract

With the purpose of the study of organism systemic immune response to the use of the cement and cementless fixation of endoprostheses in the nearest and remote terms after implantation the analysis of the indices of the immune state of 109 patients with gonarthrosis and coxarthrosis of III stage aged from 40 to 73 was carried out. The authors draw a conclusion that the reaction of immune system to actively functioning implant makes itself by the moderate activation of humoral immunity and the hyperproduction of TNFa against the background of the moderate depression of a cellular component of immune system. The dynamics of the indices of systemic immune response to large joints replacement are conditioned by surgical intervention directly and don't depend on the type of the fixation of implant.

References

  1. Гайдышев, И.П. Анализ и обработка данных : спец. справ. / И.П. Гайдышев. - СПб.: Питер, 2001. - 752 с.
  2. Имплантационные материалы и остеогенез. Роль биологической фиксации и остеоинтеграции в реконструкции кости / Н.А. Корж [и др.] // Ортопедия, травматология. - 2005. - № 4. - С. 118-127.
  3. Куропаткин, Г.В. Костный цемент в травматологии и отропедии / Г.В. Куропаткин. - Самара, 2006. - 48 с.
  4. Схемы назначения препаратов, регулирующих интенсивность стрессового ремоделирования вокруг имплантата, при эндопротезировании тазобедренного сустава : пособие для врачей / ГУН ЦНИИТО им. Н.Н. Приорова; сост. : С.П. Миронов [и др.]. - М., 2002. - 14 с.
  5. Экспериментальное обоснование применения хирургического цемента с использованием результатов для эндопротезирования тазобедренного сустава в клинике / Н.В. Загородний [и др.] // Вестник РУДН. - 2002. - №2. - С. 136-138.
  6. Bejui, J. Bone remodeling of a modular femoral stem / J. Bejui, M.H. Fessy//ActaOrthop. Belg. - 1993. -Vol. 59, Suppl. 1. - P. 356-360.
  7. Does bone quality predict loosening of cemented total hip replacements- / M. Nixon [et al.] // J. Bone Joint Surg. - 2007. - Vol. 89-B, N 10. - P. 1303-1308.
  8. Five-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis / G. Digas, J. Karrholm, J. Thanner, P. Herberts // Acta Orthop. - 2007. - Vol. 78, N 6. - P. 746-754.
  9. Hallab, N.S. Spinal implant debris-induced osteolysis / N.S. Hallab, B.M. Cunningham, J J. Jacobs // Spine. - 2003. - Vol. 28, N 20. - P. 152-138.
  10. Minimum 10-year survival of Kerboull cemented stems according to surface finish / M. Hamadouche, F. Baque, N. Lefevre, M. Kerboull // Clin. Orthop. - 2008. - Vol. 466, N2. - P. 332-339.
  11. Revision total hip arthroplasty for pelvic osteolysis with well-fixed cementless cup / J.D. Chang [et al.] // J. Arthroplasty. - 2007. - Vol. 22, N 7. - P. 987-992.
  12. Surface finish mechanics explain different clinical survivorship of cemented femoral stems for total hip arthroplasty / B. Beksac, N.A. Taveras, A.G. Valle, E.A. Salvati // J. Long Term. Eff. Med. Implants. - 2006. - Vol. 16, N 6. - P. 407-422.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2008 Chepeleva M.V., Volokitina E.A., Shved N.S., Kolotygin D.A.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies