EXPERIMENTAL STUDY OF FIXATION HARDNESS USING DIFFERENT CONSTRUCTIONS ON MODEL OF COMMINUTED PROXIMAL ULNAR FRACTURE
- Authors: Zhabin G.I.1, Al-Salmi A.2, Rumakin V.P.1
-
Affiliations:
- ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России
- СПб ГУЗ «Городская больница №26»
- Issue: Vol 17, No 3 (2011)
- Pages: 61-67
- Section: Theoretical and experimental studies
- Submitted: 11.11.2016
- Accepted: 11.11.2016
- Published: 30.09.2011
- URL: https://journal.rniito.org/jour/article/view/462
- DOI: https://doi.org/10.21823/2311-2905-2011-0-3-61-67
- ID: 462
Cite item
Full Text
Abstract
Testing of internal fixation hardness of proximal ulnar fractures (simulated) with different internal extramedullar fixators was performed (hardness for break, hardness for tension, hardness for torsion). Hardness for break and tension appeared sufficient for all internal extramedullar fixators. On the other hand, hardness for torsion was different. It increased for fracture fixed with additional screw through three fragments for all fixators and for fracture fixed with long compressive screw and plate (patent).
Keywords
About the authors
G. I. Zhabin
ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России
Author for correspondence.
Email: jgito44@yahoo.com
д.м.н., профессор, руководитель отделения восстановительной хирургии конечностей Россия
A. Al-Salmi
СПб ГУЗ «Городская больница №26»
Email: fake@neicon.ru
врач травматолог-ортопед Россия
V. P. Rumakin
ФГБУ «Российский научно-исследовательский институт травматологии и ортопедии им. Р.Р. Вредена» Минздравсоцразвития России
Email: fake@neicon.ru
к.м.н., старший научный сотрудник экспериментально-морфологического отделения Россия
References
- Волощенко, К.А. Остеосинтез стягивающей петлей при переломах надколенника и локтевого отростка : автореф. дис. … канд. мед. наук / Волощенко К.А. – М., 1983. – 20 с.
- Иванов, В.И. Оперативное лечение закрытых переломов костей локтевого сустава : автореф. дис. ... канд. мед. наук / Иванов В.И. – М., 1991. – 20 с.
- Buijze, G.A. Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating / G.A. Buijze [et al.] // Arch. Orthop. Trauma Surg. – 2010. – Vol. 130, N 4 – P.
- Edwards, S.G. Comparison of olecranon plate fixation in osteoporotic done: do current technologies and designs make a difference? / S.G. Edwards [et al.] // J. Orthop. Trauma. – 2011. – Vol. 25, N 5. – P. 306–311.
- Fife, I.S. Methods of fixation of olecranon fractures / I.S. Fife, M.M. Mossad, B.J. Holdsworth // J. Bone Joint Surg. – 1985 – Vol. 67–B, N 3. – P. 367–372.
- Hutchinson, D.T. Cyclic loading of olecranon fracture fixation constructs / D.T. Hutchinson [et al.] // J. Bone Joint Surg. – 2003. – Vol. 85-A. – P. 831–837.
- Molloy, S. Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures/ S. Molloy [et al.] // Orthop. Trauma. – 2004. – Vol. 18, N 3. – P. 170–174.
- Morrey, B. Th e elbow and its disorders / B. Morrey. – Philadelphia, London, New York, 2000. – 934 p.
- Sadri, H. Transverse fractures of the olecranon: a biomechanical comparison of three fixation techniques / H. Sadri [et al.] // Arch. Orthop. Trauma Surg. – 2011. – Vol. 131, N 1. – P. 131–138.
- Wilson, J. Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon / J. Wilson, A. Bajwa, V. Kamath, A. Rangan // J. Bone Joint Surg. – 2011. – Vol. 93–B, N 2. – P. 245–250.