<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="editorial" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Traumatology and Orthopedics of Russia</journal-id><journal-title-group><journal-title xml:lang="en">Traumatology and Orthopedics of Russia</journal-title><trans-title-group xml:lang="ru"><trans-title>Травматология и ортопедия России</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2311-2905</issn><issn publication-format="electronic">2542-0933</issn><publisher><publisher-name xml:lang="en">Vreden National Medical Research Center of Traumatology and Orthopedics</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">1647</article-id><article-id pub-id-type="doi">10.21823/2311-2905-1647</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Comments</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Комментарии</subject></subj-group><subj-group subj-group-type="article-type"><subject>Editorial</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Editorial Comment on the Article by A.S. Zolotov et al. “The Optimal Surgical Needle for Tendon Suture: Cutting Edge or Reverse Cutting Edge?”</article-title><trans-title-group xml:lang="ru"><trans-title>Редакционный комментарий к статье А.С. Золотова с соавторами «Оптимальная игла для шва сухожилий: традиционная режущая или обратно-режущая?»</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Sereda</surname><given-names>A. P.</given-names></name><name xml:lang="ru"><surname>Середа</surname><given-names>А. П.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="ru"><p>член редколлегии журнала, д-р мед. наук заместитель директора </p></bio><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en"></institution></aff><aff><institution xml:lang="ru">ФГБУ «Национальный медицинский исследовательский центр &#13;
травматологии и ортопедии им. Р.Р. Вредена» Минздрава России по инновациям и развитию </institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2021-07-13" publication-format="electronic"><day>13</day><month>07</month><year>2021</year></pub-date><volume>27</volume><issue>2</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>81</fpage><lpage>83</lpage><history><date date-type="received" iso-8601-date="2021-07-12"><day>12</day><month>07</month><year>2021</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; ,</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; ,</copyright-statement><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/></permissions><self-uri xlink:href="https://journal.rniito.org/jour/article/view/1647">https://journal.rniito.org/jour/article/view/1647</self-uri><abstract xml:lang="en"><p>.</p></abstract><trans-abstract xml:lang="ru"><p>.</p></trans-abstract><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>1. Smith G.C., Pell J.P. Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomised controlled trials. BMJ. 2003;327(7429):1459-1461. doi: 10.1136/bmj.327.7429.1459.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>2. Yeh R.W., Valsdottir L.R., yeh M.W., Shen C., Kramer D.B., Strom J.B. et al. PARACHUTE Investigators. Parachute use to prevent death and major trauma when jumping from aircraft: randomized controlled trial. BMJ. 2018;363:k5094. doi: 10.1136/bmj.k5094. Erratum in: BMJ. 2018;363:k5343.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>3. Трапезников А.В. О механической прочности различных швов сухожилий. Итоговая конф. ВНО слушателей ВМедА им. С.М. Кирова 12 апреля 1983 г. Воен.-мед. акад. : Тез. докл. Л.; 1983. С. 277-277.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>4. Cretnik A., Zlajpah L., Smrkolj V., KosanovićM. The strength of percutaneous methods of repair of the Achilles tendon: a biomechanical study. Med Sci Sports Exerc. 2000;32(1):16-20. doi: 10.1097/00005768-200001000-00004.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>5. McKeon B.P., Heming J.F., Fulkerson J., Langeland R. The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures. Arthroscopy. 2006;22(1):33-37. doi: 10.1016/j.arthro.2005.10.008.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>6. Watson T.W., Jurist K.A., yang K.H., Shen K.L. The strength of Achilles tendon repair: an in vitro study of the biomechanical behavior in human cadaver tendons. Foot Ankle Int. 1995;16(4):191-195. doi: 10.1177/107110079501600404.</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>7. Zandbergen RA, de Boer SF, Swierstra BA, Day J, Kleinrensink GJ, Beumer A Surgical treatment of Achilles tendon rupture. Examination of strength of 3 types of suture techniques in a cadaver model. Acta Orthop.2005;76(3):408-411.</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>8. Середа А.П. Хирургическое лечение разрывов ахиллова сухожилия. Дис. ... д-ра мед. наук. Москва, 2015. 280 с.</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>9. Gelberman R.H., Boyer M.I., Brodt M.D., Winters S.C., Silva M.J. The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons. An experimental study on the early stages of tendonhealing in dogs. J Bone Joint Surg Am. 1999;81(7):975-982. doi: 10.2106/00004623-199907000-00010.</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>10. Sandow M.J., McMahon M. Single-cross grasp six-strand repair for acute flexor tenorrhaphy: Modified Savage technique. In: Taras J.S., Schneider L.H. (eds). Atlas hand clinics. Philadelphia, Saunders;1996:41-64.</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>11. Winters S.C., Seiler J.G. 3rd, Woo S.L., Gelberman R.H. Suture methods for flexor tendon repair. A biomechanical analysis during the first six weeks following repair. Ann Chir Main Memb Super. 1997;16(3):229-234. doi: 10.1016/s0753-9053(97)80006-3.</mixed-citation></ref><ref id="B12"><label>12.</label><mixed-citation>12. Winters S.C., Gelberman R.H., Woo S.L., Chan S.S., Grewal R., Seiler J.G. 3rd. The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: a biomechanical study in dogs. J Hand Surg Am. 1998;23(1):97-104. doi: 10.1016/s0363-5023(98)80096-8.</mixed-citation></ref><ref id="B13"><label>13.</label><mixed-citation>13. Ефименко Н.А., Грицюк А.А., Гаврюшенко Н.С., Середа А.П., Кулешов Д.Н. Оптимальный шов ахиллова сухожилия (клинико-экспериментальное ис-следование). Московский хирургический журнал.2011;19(3):44-50.</mixed-citation></ref><ref id="B14"><label>14.</label><mixed-citation>14. Benthien R.A., Aronow M.S., Doran-Diaz V., Sullivan R.J., Naujoks R., Adams D.J. Cyclic loading of Achilles tendon repairs: a comparison of polyester and polyblend suture. Foot Ankle Int. 2006;27(7):512-518. doi: 10.1177/107110070602700706.</mixed-citation></ref><ref id="B15"><label>15.</label><mixed-citation>15. Herbort M., Haber A., Zantop T., Gosheger G., Rosslenbroich S., Raschke M.J., Petersen W. Biomechanical comparison of the primary stability of suturing Achilles tendon rupture: a cadaver study of Bunnell and Kessler techniques under cyclic loading conditions. Arch Orthop Trauma Surg. 2008;128(11):1273-1277. doi: 10.1007/s00402-008-0602-1.</mixed-citation></ref><ref id="B16"><label>16.</label><mixed-citation>16. Lee S.J., Sileo M.J., Kremenic I.J., Orishimo K., BenAvi S., Nicholas S.J. et al. Cyclic loading of 3 Achilles tendon repairs simulating early postoperative forces. Am J Sports Med. 2009;37(4):786-790. doi: 10.1177/0363546508328595.</mixed-citation></ref><ref id="B17"><label>17.</label><mixed-citation>17. Barber F.A., Howard M.S., Piccirillo J., Spenciner D.B. A Biomechanical Comparison of Six Suture Configurations for Soft Tissue-Based Graft Traction and Fixation. Arthroscopy. 2019;35(4):1163-1169. doi: 10.1016/j.arthro.2018.10.140.</mixed-citation></ref><ref id="B18"><label>18.</label><mixed-citation>18. Camarda L., Pitarresi G., Fazzari F., Tumino D., D’Arienzo M. Biomechanical comparison between the modified rolling-hitch and the modified finger-trap suture techniques. Arch Orthop Trauma Surg. 2016;136(11):1595-1600. doi: 10.1007/s00402-016-2551-4.</mixed-citation></ref></ref-list></back></article>
