Long-Term Results of Total Hip Arthroplasty with RM Classic Cups

Cover Page


Cite item

Abstract

Relevance. The RM Classic monoblock titanium-coated polyethylene cup is widely used in the total hip arthroplasty. However, so far in Russia there has been no analysis of follow-up over 10 years for a limited number of patients in a single hospital. The aim of the study was to evaluate the long-term outcomes of total hip replacement with RM Classic acetabular component. Materials and Methods. The outcomes of 328 total hip arthroplasties (289 patients operated in the period from 1997 to 2007) with RM Classic cups were evaluated in a monocentral retrospective clinical study. The average follow-up period was 14.4 years. Revision procedure due to aseptic loosening, polyethylene wear or osteolysis was considered as the end point of the study. Results. 9 revisions during the short and medium follow-up periods (up to 10 years) were associated with malpositioning of RM Classic components and errors in surgical technique. The indications for later revision THA (19 cases) were polyethylene wear and aseptic loosening. Only in one case they were combined with pelvic bone osteolysis with the formation of III a defect according to W.G. Paprosky classification. Within 15 years the Kaplan-Meier survivorship of RM Classic cup was 92.5%. There was a statistically significant difference of the survival curves in the ceramic-on-poly against metal-on-poly bearings: 94.9% and 79.4%, respectively. The average Harris Hip Score was 88.6. Conclusion. RM Classic uncemented monoblock cup has proven its high efficiency and survival in 15 years follow-up period and over.

About the authors

V. V. Danilyak

Yaroslavl Regional Clinical Hospital of War Veterans — International Center “Healthy Longevity”

Author for correspondence.
Email: v-danilyak@mail.ru

Cand. Sci. (Med.), Chief of Orthopedic Department

Yaroslavl

Russian Federation

V. V. Klyuchevsky

Yaroslavl Regional Clinical Hospital of War Veterans – International Center “Healthy Longevity”

Email: fake@neicon.ru

Cand. Sci. (Med.), Assistant Professor at Faculty Of Traumatology and Orthopedics, Yaroslavl State Medical University; Orthopedic Surgeon
of Orthopedic Department  

Yaroslavl

Russian Federation

M. A. Molodov

Yaroslavl Regional Clinical Hospital of War Veterans – International Center “Healthy Longevity”

Email: fake@neicon.ru

Cand. Sci. (Med.), Resident Surgeon of Orthopedic Department

Yaroslavl

Russian Federation

E. V. Goryunov

Yaroslavl State Medical University

Email: fake@neicon.ru

PhD Student, Faculty of Traumatology and Orthopedics

Yaroslavl

Russian Federation

K. V. Marchenkova

Yaroslavl State Medical University

Email: fake@neicon.ru

Resident Surgeon, Faculty of Traumatology and Orthopedics

Yaroslavl

Russian Federation

References

  1. Mathys R. The RM cup: from the idea to the product. In: Bergmann E.G. (ed.). Hip-Joint Surgery: the RM Cup : monograph of a coated acetabular implant. Reinbek : Einhorn-Presse; 1998. p. 10-16.
  2. Witzel U. Distribution of stress in a hemispherical RM cup and its bony bed. In: Horne G. (ed.). Hip-joint surgery : the RM cup : long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 29-41.
  3. Dryagin V.G., Kuropatkin G.V., Danilyak V.V. RM cup: experiences in Russia. In: Horne G. (ed.). Hip-joint surgery: the RM cup : long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 57-64.
  4. Mathys R. History — how the successful story of the RMClassic Cup started. Horne G. (ed.). Hip-joint surgery: the RM cup : long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 11-15.
  5. Kini S.G., Anwar R., Bruce W., Walker P. Modular versus monoblock cementless acetabular cups in primary total hip arthroplasty — a review. Int J Orthop. 2014;1(3): 93-99. doi: 10.6051/j.issn.2311-5106.2014.01.22
  6. Heirholzer G., Jukema G.N. The uncemented Robert Mathys cup. In: Horne G. (ed.). Hip-joint surgery : the RM cup: long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 62-73.
  7. Bayliss L.E., Culliford D., Monk A.P., Glyn-Jones S., Prieto-Alhambra D., Judge A. et al. The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study. Lancet. 2017;389(10077):1424-1430. doi: 10.1016/S0140-6736(17)30059-4.
  8. Pakvis D., Biemond L., van Hellemondt G., Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop. 2011;35:1445-1451. doi: 10.1007/s00264-010-1120-7.
  9. Ihle M., Mai S., Pfluger D., Siebert W. The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg Br. 2008; 90(10):1284-1290. doi: 10.1302/0301-620X.90B10.20274.
  10. Diks M.J., van den Broek C.M., Anderson P.G., van Limbeek J., Spruit M. The uncemented, titanium-coated RM cup: Survival and analyses of failures. Hip Int. 2005; 15(2):71-77. doi: 10.5301/HIP.2008.5274.
  11. Young A.M., Sychterz C.J., Hopper R.H. jr., Engh C.A. Effect of Acetabular Modularity on Polyethylene Wear and Osteolysis in Total Hip Arthroplasty. J Bone Joint Surg Am. 2002;84(1):58-63. doi: 10.2106/00004623-200201000-00009.
  12. Horne G., Devane P.A., Dalton D. Does pelvic osteolysis occur with a nonmodular uncemented acetabular component? J Arthroplasty. 2006;21(2):185-190. doi: 10.1016/j.arth.2005.05.010.
  13. Gwynne-Jones P.D., Garneti N., Wainwright C., Matheson J.A., King R. The Morscher Press Fit acetabular component. A nine to 13-year review. J Bone Joint Surg Br. 2009;91(7):859-864. doi: 10.1302/0301-620X.91B7.22013.
  14. Krieg A.H., Speth B.M., Ochsner P.E. Backside volumetric change in the polyethylene of uncemented acetabular components. J Bone Joint Surg Br. 2009;91(8): 1037-1043. doi: 10.1302/0301-620X.91B8.21850.
  15. Judas F.J., Dias R.F., Lucas R.M. A technique to remove a well-fixed titanium-coated RM acetabular cup in revision hip arthroplasty. J Orthop Surg Res. 2011; 6(1):31. doi: 10.1186/1749-799X-6-31.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c)



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 82474 от 10.12.2021.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies